Publication:
Colorimetric assay for determination of Cu (II) ions using L-cysteine functionalized silver nanoplates

dc.contributor.authorNapakporn Poosinuntakulen_US
dc.contributor.authorTewarak Parnklangen_US
dc.contributor.authorThitikan Sitiweden_US
dc.contributor.authorSudkate Chaiyoen_US
dc.contributor.authorSumana Kladsomboonen_US
dc.contributor.authorOrawon Chailapakulen_US
dc.contributor.authorAmara Apiluxen_US
dc.contributor.otherKing Mongkuts University of Technologyen_US
dc.contributor.otherChulalongkorn Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2020-08-25T09:27:13Z
dc.date.available2020-08-25T09:27:13Z
dc.date.issued2020-11-01en_US
dc.description.abstract© 2020 Elsevier B.V. A L-cysteine-modified silver nanoplate (L-cys-AgNPl)-based colorimetric assay was developed for simple and rapid screening for copper (II) ions (Cu2+) in aqueous solution. The assay is based on the Cu2+-induced aggregation of L-cys-AgNPls. In the presence of Cu2+, L-cys-AgNPls were aggregated immediately and the color of solution was distinctly changed from violet to blue within 5 min. This method enabled the quantitative measurement of Cu2+ with sample volumes as low as 5 µL. Under optimized conditions, the limit of detection (LOD) was 1 ppm and 0.34 ppm by naked eye and smartphone with RGB application, respectively. For quantitative analysis, the calibration curve was constructed by plotting the differences in absorbance ratio at wavelengths of 620 nm and 570 nm (A620/A570) of sample and blank as a function of Cu2+ concentration. This assay detected Cu2+ in the range of 0.25 to 6 ppm (R2 = 0.9951) and the LOD was 0.22 ppm. In addition, L-cys-AgNPls exhibited good selectivity for Cu2+. Additionally, the developed method was successfully applied for rapid screening of Cu2+ in real wastewater samples with % recovery in the range of 73.08 to 114.62 and 93.48 to 114.04 by UV-visible spectrometry and smartphone with RGB application, respectively. The results from the developed method were compared with those from atomic absorption spectrometry and no significant difference was found between the two methods. The developed colorimetric method is promising for on-site detection of Cu2+ with high accuracy, good selectivity, and minimal reagent consumption.en_US
dc.identifier.citationMicrochemical Journal. Vol.158, (2020)en_US
dc.identifier.doi10.1016/j.microc.2020.105101en_US
dc.identifier.issn0026265Xen_US
dc.identifier.other2-s2.0-85086522234en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/57804
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086522234&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleColorimetric assay for determination of Cu (II) ions using L-cysteine functionalized silver nanoplatesen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086522234&origin=inwarden_US