Publication: HPLC-fluorescent analysis of memantine: An investigation on fluorescent derivative formation
dc.contributor.author | Pornpan Prapatpong | en_US |
dc.contributor.author | Thanayu Techa-In | en_US |
dc.contributor.author | Wantaporn Padungpuak | en_US |
dc.contributor.author | Sawanya Buranaphalin | en_US |
dc.contributor.author | Leena Suntornsuk | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.date.accessioned | 2018-11-23T09:58:33Z | |
dc.date.available | 2018-11-23T09:58:33Z | |
dc.date.issued | 2015-01-01 | en_US |
dc.description.abstract | © 2015 Pornpan Prapatpong et al. Memantine is an N-methyl-D-aspartate receptor antagonist recommended for treatment of Alzheimer's disease. Due to the lack of chromophores/fluorophores in memantine molecule, this work focuses on a novel procedure for memantine-fluorescent derivative formation enabling it to be monitored by a fluorescence detector. 4-(N-Chloroformylmethyl-N-methyl)amino-7-N,N-dimethylaminosulphonyl 2,1,3-benzoxadiazole (DBD-COCl) was chosen as a fluorescent probe since the carbonyl chloride of DBD-COCl could easily react with the amine on memantine to form the fluorescent derivative. The derivatization was achieved at 5: 1 of DBD-COCl and memantine, at 60°C for 50 min. Structure elucidation from mass spectrometry and infrared spectroscopy spectra confirmed the amide bond of memantine-DBD-COCl. The derivative was stable up to 24 h and could be monitored by high performance liquid chromatography (HPLC) coupled with a fluorescence detector using a VertiSep GES C18 column, acetonitrile and water (80: 20) as the mobile phase with a flow rate of 1 mL/min using the excitation and emission wavelengths at 430 and 520 nm, respectively. The derivative was eluted at 4.50 min and was separated from the DBD-COCl. Preliminary validation data reveals good linearity (r2≥0.99), repeatability (%RSD < 0.54) and accuracy (%R between 94 and 119%) with a limit of detection of 0.79 g/mL. | en_US |
dc.identifier.citation | Journal of Chemistry. Vol.2015, (2015) | en_US |
dc.identifier.doi | 10.1155/2015/672183 | en_US |
dc.identifier.issn | 20909071 | en_US |
dc.identifier.issn | 20909063 | en_US |
dc.identifier.other | 2-s2.0-84924122980 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/35765 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84924122980&origin=inward | en_US |
dc.subject | Chemistry | en_US |
dc.title | HPLC-fluorescent analysis of memantine: An investigation on fluorescent derivative formation | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84924122980&origin=inward | en_US |