Publication:
Diagnostic accuracy of peripheral venous lactate and the 2009 WHO warning signs for identifying severe dengue in Thai adults: a prospective observational study

dc.contributor.authorVipa Thanachartweten_US
dc.contributor.authorAnan Wattanathumen_US
dc.contributor.authorOer-areemitr, Nitthaen_US
dc.contributor.authorAkanitt Jittmittraphapen_US
dc.contributor.authorDuangjai Sahassanandaen_US
dc.contributor.authorChalida Monpassornen_US
dc.contributor.authorManoon Surabotsophonen_US
dc.contributor.authorVarunee Desakornen_US
dc.contributor.otherMahidol University. Faculty of Tropical Medicine. Department of Clinical Tropical Medicineen_US
dc.date.accessioned2017-11-15T08:13:23Z
dc.date.available2017-11-15T08:13:23Z
dc.date.created2017-11-15
dc.date.issued2016
dc.description.abstractBackground: Dengue is the most common mosquito-borne viral disease in humans. However, the sensitivities of warning signs (WSs) for identifying severe dengue in adults are low, and the utility of lactate levels for identifying severe dengue in adults has not been verified. Therefore, we aimed to evaluate the diagnostic accuracy of using peripheral venous lactate levels (PVL), as well as WSs established by the World Health Organization, for identifying severe dengue. Methods: We prospectively evaluated individuals hospitalized for dengue who were admitted to the Hospital for Tropical Diseases in Thailand between May 2013 and January 2015. Blood samples to evaluate PVL levels were collected at admission and every 24 h until the patient exhibited a body temperature of <37.8 °C for at least 24 h. Data were recorded on a pre-defined case report form, including baseline characteristics, clinical parameters, and laboratory findings. Results: Among 125 patients with confirmed dengue, 105 (84.0 %) patients had non-severe dengue, and 20 (16.0 %) patients had severe dengue. The presence of clinical fluid accumulation as a WS provided high sensitivity (75.0 %, 95 % confidence interval [CI]: 50.9–91.3 %) and specificity (90.5 %, 95 % CI: 83.2–95.3 %). The PVL level at admission was used to evaluate its diagnostic value, and receiver operating characteristic curve analysis revealed an area under the curve of 0.84 for identifying severe dengue. At the optimal cutoff value (PVL: 2.5 mmol/L), the sensitivity and specificity were 65.0 % (95 % CI: 40.8–84.6 %) and 96.2 % (95 % CI: 90.5–99.0 %), respectively. A combined biomarker comprising clinical fluid accumulation and/or PVL of ≥2.5 mmol/L provided the maximum diagnostic accuracy for identifying severe dengue, with a sensitivity of 90.0 % (95 % CI: 68.3–98.8 %) and a specificity of 87.6 % (95 % CI: 79.8–93.2 %). Conclusions: Clinical fluid accumulation and/or PVL may be used as a diagnostic biomarker of severe dengue among adults. This biomarker may facilitate early recognition and timely treatment of patients with severe dengue, which may reduce dengue-related mortality and hospital burden.en_US
dc.identifier.citationBMC Infectious Diseases. Vol.16, (2016), 46en_US
dc.identifier.doi10.1186/s12879-016-1386-5
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/3151
dc.language.isoengen_US
dc.rightsMahidol Universityen_US
dc.rights.holderBioMed Centralen_US
dc.subjectOpen Access articleen_US
dc.subjectSevere dengueen_US
dc.subjectLactateen_US
dc.subjectWarning signsen_US
dc.subjectDiagnostic accuracyen_US
dc.subjectProspective studyen_US
dc.titleDiagnostic accuracy of peripheral venous lactate and the 2009 WHO warning signs for identifying severe dengue in Thai adults: a prospective observational studyen_US
dc.typeResearch Articleen_US
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
tm-ar-vipa-2016.pdf
Size:
551.12 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections