Publication:
Simple flow injection for screening of total antioxidant capacity by amperometric detection of DPPH radical on carbon nanotube modified-glassy carbon electrode

dc.contributor.authorM. Amatatongchaien_US
dc.contributor.authorS. Laosingen_US
dc.contributor.authorO. Chailapakulen_US
dc.contributor.authorD. Nacaprichaen_US
dc.contributor.otherUbon Rajathanee Universityen_US
dc.contributor.otherFlow Innovation-Research for Science and Technology Laboratories (FIRST Labs.en_US
dc.contributor.otherChulalongkorn Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-06-11T04:42:48Z
dc.date.available2018-06-11T04:42:48Z
dc.date.issued2012-08-15en_US
dc.description.abstractAn amperometric flow injection (FI) method suitable for evaluation of 'total antioxidant capacity' (TAC) is presented. In this method, a carrier stream of a solution of 2,2-diphenyl-1-picrylhydrazyl radical (DPPH • ) continuously flows through an electrochemical cell, furnished with a carbon nanotube modified-glassy carbon electrode (CNT/GC) as the working electrode. At the applied voltage of 0.05 V (vs. Ag/AgCl), DPPH • is reduced resulting in a constant electric current. For measurement of the TAC, a sample zone containing antioxidant(s) is injected into the carrier stream therein reduction reaction of DPPH • occurring within the sample zone. The decreased amount of the radical in the sample zone leads to a drop of the amperometric signal at the CNT/GC electrode. We have also compared the performance of the CNT/GC electrode to the unmodified GC electrode using cyclic voltammetry. The sensitivity of the CNT/GC electrode was more than twenty five times greater than the bare GC electrode. The study of the sweep rate dependence showed that the cathodic and anodic current of 0.1 mM DPPH solution varied linearly (r 2 =0.998) with the square root of the scan rate, from 0.02 to 0.12 Vs -1 . These results demonstrated that the CNT/GC electrode is appropriate for the quantitation of antioxidants via amperometric detection of the residual concentration of non-reacted DPPH • . We obtained linear calibrations for all the antioxidants tested including gallic acid, catechin, quercetin, caffeic acid and Trolox. The system offers rapid sample throughput (45 samples h -1 ) and good precision of 3.2% R.S.D., for 20 μL-injection of 2.5 μM Trolox (n=30). This method was applied to evaluate the TAC of extracts of some Thai indigenous vegetables. © 2012 Elsevier B.V. All rights reserved.en_US
dc.identifier.citationTalanta. Vol.97, (2012), 267-272en_US
dc.identifier.doi10.1016/j.talanta.2012.04.029en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-84864365164en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/13951
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84864365164&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleSimple flow injection for screening of total antioxidant capacity by amperometric detection of DPPH radical on carbon nanotube modified-glassy carbon electrodeen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84864365164&origin=inwarden_US

Files

Collections