Publication: Diagnostic accuracy of a loop-mediated isothermal PCR assay for detection of Orientia tsutsugamushi during acute scrub typhus infection
Issued Date
2011-09-01
Resource Type
ISSN
19352735
19352727
19352727
Other identifier(s)
2-s2.0-80053460822
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Bibliographic Citation
PLoS Neglected Tropical Diseases. Vol.5, No.9 (2011)
Suggested Citation
Daniel H. Paris, Stuart D. Blacksell, Pruksa Nawtaisong, Kemajittra Jenjaroen, Achara Teeraratkul, Wirongrong Chierakul, Vanaporn Wuthiekanun, Pacharee Kantipong, Nicholas P J Day Diagnostic accuracy of a loop-mediated isothermal PCR assay for detection of Orientia tsutsugamushi during acute scrub typhus infection. PLoS Neglected Tropical Diseases. Vol.5, No.9 (2011). doi:10.1371/journal.pntd.0001307 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/12360
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
Diagnostic accuracy of a loop-mediated isothermal PCR assay for detection of Orientia tsutsugamushi during acute scrub typhus infection
Other Contributor(s)
Abstract
Background: There is an urgent need to develop rapid and accurate point-of-care (POC) technologies for acute scrub typhus diagnosis in low-resource, primary health care settings to guide clinical therapy. Methodology/Principal Findings: In this study we present the clinical evaluation of loop-mediated isothermal PCR assay (LAMP) in the context of a prospective fever study, including 161 patients from scrub typhus-endemic Chiang Rai, northern Thailand. A robust reference comparator set comprising following 'scrub typhus infection criteria' (STIC) was used: a) positive cell culture isolate and/or b) an admission IgM titer ≥1:12,800 using the 'gold standard' indirect immunofluorescence assay (IFA) and/or c) a 4-fold rising IFA IgM titer and/or d) a positive result in at least two out of three PCR assays. Compared to the STIC criteria, all PCR assays (including LAMP) demonstrated high specificity ranging from 96-99%, with sensitivities varying from 40% to 56%, similar to the antibody based rapid test, which had a sensitivity of 47% and a specificity of 95%. Conclusions/Significance: The diagnostic accuracy of the LAMP assay was similar to realtime and nested conventional PCR assays, but superior to the antibody-based rapid test in the early disease course. The combination of DNA- and antibody-based detection methods increased sensitivity with minimal reduction of specificity, and expanded the timeframe of adequate diagnostic coverage throughout the acute phase of scrub typhus. © 2011 Paris et al.
