Publication:
An investigation on a trachea air flow pattern in an intubated patient: Airway edema case

dc.contributor.authorA. Sanpanichen_US
dc.contributor.authorM. Masomtoben_US
dc.contributor.authorP. Phasukkiten_US
dc.contributor.authorY. Kajornpredanonen_US
dc.contributor.authorS. Daochaien_US
dc.contributor.authorW. Sroykhamen_US
dc.contributor.authorK. Petsarben_US
dc.contributor.authorC. Phairohen_US
dc.contributor.authorW. Angkhananuwaten_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherThailand National Metal and Materials Technology Centeren_US
dc.contributor.otherKing Mongkut's Institute of Technology Ladkrabangen_US
dc.contributor.otherWestern Universityen_US
dc.date.accessioned2018-12-21T07:32:21Z
dc.date.accessioned2019-03-14T08:03:35Z
dc.date.available2018-12-21T07:32:21Z
dc.date.available2019-03-14T08:03:35Z
dc.date.issued2017-12-19en_US
dc.description.abstract© 2017 IEEE. In a respiratory failure patient, an artificial ventilation is commonly performed by using a mechanical ventilator particularly in an ICU ward. On such a case, an endotracheal tube (ETT) must be inserted into patient's airway and following by a balloon cuff blowing in order to fix and act as a sealed artificial airway for an artificial ventilation. However, those implementations adversely affect to tracheal tissue-epithelial layer and probably damaging a larynx and vocal cord zone. After a ventilator weaning and an extubating process, some patients always suffering with a larynx or tracheal edema symptom or postextubation stridor (PES) in which patient airway is narrowed or swelling due to a long term pressurization by the ETT balloon cuff. This mainly causes a difficulty in a spontaneous breathing. In general, a cuff leak test is a common medical maneuver used in order to predict a larynx or tracheal edema possibility after ETT was removed. Air volume different between an inspired volume (Vtì) and an expired volume (Vie) normally should be higher than 100 mL or 10%. In this paper, we propose an investigation of an airflow pattern on an intubated patient in the cuff leak test process in order to understand and support a prediction of the tracheal edema before perform an ETT extubation. The study was performed in an intubated trachea by using a simulation of an airflow pattern, air volume prediction in a normal intubated case and during cuff leak test process with no edema and edema case. Although, this simulation was intently implemented in a simple intubated trachea model, however the obtain results imply us a practical information and will be used as a basic implementation for a further study, especially in case of variety in the ETT intubation or cuff less ventilation even more complication case in the near future.en_US
dc.identifier.citationBMEiCON 2017 - 10th Biomedical Engineering International Conference. Vol.2017-January, (2017), 1-4en_US
dc.identifier.doi10.1109/BMEiCON.2017.8229127en_US
dc.identifier.other2-s2.0-85046348909en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/42540
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85046348909&origin=inwarden_US
dc.subjectEngineeringen_US
dc.titleAn investigation on a trachea air flow pattern in an intubated patient: Airway edema caseen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85046348909&origin=inwarden_US

Files

Collections