Publication: Efficacy evaluation of detecting and identifying bacterial endocarditis agents from blood cultures by matrix-assisted laser desorption ionization-time of flight mass spectrometry
1
Issued Date
2018-05-01
Resource Type
ISSN
01251562
Other identifier(s)
2-s2.0-85054781275
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Bibliographic Citation
Southeast Asian Journal of Tropical Medicine and Public Health. Vol.49, No.3 (2018), 428-437
Suggested Citation
Songkran Thongon, Kanda Ekcharoenkul, Amornrut Leelaporn, Pattarachai Kiratisin, Popchai Ngamskulrungroj Efficacy evaluation of detecting and identifying bacterial endocarditis agents from blood cultures by matrix-assisted laser desorption ionization-time of flight mass spectrometry. Southeast Asian Journal of Tropical Medicine and Public Health. Vol.49, No.3 (2018), 428-437. Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/46679
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
Efficacy evaluation of detecting and identifying bacterial endocarditis agents from blood cultures by matrix-assisted laser desorption ionization-time of flight mass spectrometry
Other Contributor(s)
Abstract
© 2018, SEAMEO TROPMED Network. All rights reserved. Early identification of etiologic agents of infective endocarditis is important for reducing morbidity and mortality. Therefore, we aimed to evaluate the efficacy of the matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) for the early identification of the etiologic bacterial agents of infective endocarditis in Thailand from blood cultures compared to the VITEK 2 (bioMérieux) method. Nine causative agents of endocarditis were retrieved from Siriraj hospital bacterial culture collection and evaluated: Klebsiella pneumoniae, Pseudomonas aeruginosa, Enterococcus faecalis, Staphylococcus aureus, Streptococcus oralis, Haemophilus parainfluenzae, Aggregatibacter actinomycetemcomi-tans, Cardiobacterium hominis and Eikenella corroden with the last 4 species being fastidious. E. coli cannot be differentiated from Shigella spp with the MALDI-TOF MS method therefore it was not tested in our study. Artificially created positive blood cultures were used for this study. Each bacterial suspension mixed with human blood was injected into a blood culture bottle (BACTEC TM FX blood culture system). An initial bacterial concentration of 10-100 CFU/ml in the blood culture was used to simulate the bacterial concentration typically found in the blood of a bacterial endocarditis patient. Time to bacterial identification of these cultures using the VITEK 2 method and the MALDI-TOF MS method were compared. Since the manufacturer (Bruker Daltonics) MALDI-TOF MS database is limited, we created our own in-house (Siriraj Hospital) MALDI-TOF MS database and combined it with the manufacturer’s database. Only non-fastidious bacteria were consistently identified to the species level with the MALDI-TOF MS method but both fastidious and non-fastidious bacteria were detected with the VITEK 2 method. The MALDI-TOF MS method identified the studied non-fastidious bacteria to the species level from the blood cultures faster than the VITEK 2 method (7.2-12.7 hours versus 57.2 – 63.8 hours; p < 0.001). The optimal time to identification of H. parainfluenzae could not to be determined for the MALDI-TOF MS method since the.
