Publication:
Custom-made oral appliances for the treatment of obstructive sleep apnea: Outcomes in Thai patients

dc.contributor.authorRachareeya Suksangeamen_US
dc.contributor.authorWish Banhiranen_US
dc.contributor.authorPhawin Keskoolen_US
dc.contributor.authorWattanachai Chotinaiwatarakulen_US
dc.contributor.authorCheerasook Chongkolwatanaen_US
dc.contributor.authorParaya Assanasenen_US
dc.contributor.authorSomsak Mitrirattanakulen_US
dc.contributor.authorPimnaraporn Putongkamen_US
dc.contributor.otherSiriraj Hospitalen_US
dc.contributor.otherMahidol University, Faculty of Dentistryen_US
dc.date.accessioned2022-08-04T09:27:07Z
dc.date.available2022-08-04T09:27:07Z
dc.date.issued2021-04-01en_US
dc.description.abstractObjective: To evaluate the outcomes of custom-made oral appliances (OAs) for the treatment of obstructive sleep apnea (OSA) in Thai patients. Materials and Methods: A retrospective review of polysomnography (PSG) results and relevant information, including patient characteristics, visual analog scale (VAS) of sleep-associated symptoms, and Epworth Sleepiness Scale (ESS) of patients treated with an OA between January 2010 and January 2018 was done at Siriraj Hospital, Thailand. Inclusion criteria were OSA patients aged 18 years or older who underwent diagnostic and therapeutic PSG with a custom-made OA. Exclusion criteria were patients who were lost to follow-up or had incomplete PSG data. Results: Sixty-seven OSA patients were recruited. The median apnea-hypopnea index (AHI) was significantly decreased from 16.5 (11.5, 27.8) to 5.1 (2.8, 11.3) events per hour (p<0.001) and the median minimal oxygen saturation increased from 82.0 (77.0, 86.0) to 87.0 (80.0, 90.0) with OA treatment (p<0.001). ESS scores decreased from 9 (6, 13) to 7 (4, 9) (p<0.001) and the VAS of snoring loudness and frequency as rated by family members or bed partners decreased from 6 (4, 7.5) to 3.3 (2, 5) and from 5.5 (3.2, 7.6) to 3.4 (2, 5.3), respectively (p<0.001). Forty-one patients (61%) had a 50% reduction of AHI, and an AHI of less than 15 events per hour after treatment, which were considered good responses. Common adverse effects of the treatment included temporomandibular joint discomfort, dry mouth, excessive salivation, gingival pain, and toothache, but these occurred to only a mild-to-moderate degree and were tolerable. Conclusion: Custom-made OA is an effective alternative treatment for OSA in selected Thai patients, particularly for those with a mild-to-moderate degree.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.104, No.4 (2021), 571-575en_US
dc.identifier.doi10.35755/jmedassocthai.2021.04.11696en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-85104635190en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/78298
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85104635190&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleCustom-made oral appliances for the treatment of obstructive sleep apnea: Outcomes in Thai patientsen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85104635190&origin=inwarden_US

Files

Collections