Publication:
A dynamic continuous-flow dialysis system with on-line electrothermal atomic-absorption spectrometric and pH measurements for in-vitro determination of iron bioavailability by simulated gastrointestinal digestion

dc.contributor.authorJeerawan Promchanen_US
dc.contributor.authorJuwadee Shiowatanaen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-06-21T08:08:42Z
dc.date.available2018-06-21T08:08:42Z
dc.date.issued2005-07-01en_US
dc.description.abstractA dynamic continuous-flow dialysis (CFD) method with on-line electrothermal atomic absorption spectrometric (ETAAS) and pH measurements for study of simulated gastrointestinal digestion has been developed for prediction of iron bioavailability. The method used to estimate mineral bioavailability was based on gastric digestion in a batch system then dynamic continuous-flow intestinal digestion. The intestinal digestion was performed in a dialysis bag placed inside a chamber containing a flowing stream of dialyzing solution. Mineral concentration and dialysate pH were monitored by ETAAS and use of a pH meter, respectively. The amount of dialyzed minerals in the intestinal digestion stage was used to evaluate the dialyzability. The dialysis profile and pH change can be used to understand or examine differences between the dialyzability of different food samples. To test the proposed system it was used to estimate the iron dialyzability of different kinds of milk. Iron dialyzability for powdered cow milk, cereal milk, and two brands of soymilk was found to be 1.7, 20.4, 24.9, and 37.7%, respectively. The developed CFD-ETAAS-pH system is a simple, rapid, and inexpensive tool for bioavailability studies, especially for minerals at ultratrace levels. © Springer-Verlag 2005.en_US
dc.identifier.citationAnalytical and Bioanalytical Chemistry. Vol.382, No.6 (2005), 1360-1367en_US
dc.identifier.doi10.1007/s00216-005-3288-zen_US
dc.identifier.issn16182650en_US
dc.identifier.issn16182642en_US
dc.identifier.other2-s2.0-23744475260en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/16316
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=23744475260&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.titleA dynamic continuous-flow dialysis system with on-line electrothermal atomic-absorption spectrometric and pH measurements for in-vitro determination of iron bioavailability by simulated gastrointestinal digestionen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=23744475260&origin=inwarden_US

Files

Collections