Publication:
Temperature-dependent schlieren effect in liquid flow for chemical analysis

dc.contributor.authorJintana Suwanruten_US
dc.contributor.authorNattapong Chantipmaneeen_US
dc.contributor.authorWichayaporn Kamsongen_US
dc.contributor.authorSupatana Bukingen_US
dc.contributor.authorThitirat Mantimen_US
dc.contributor.authorPhoonthawee Saetearen_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.otherRamkhamhaeng Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherSrinakharinwirot Universityen_US
dc.contributor.otherFlow Innovation-Research for Science and Technology Laboratories (FIRST Labs.en_US
dc.date.accessioned2019-08-23T10:48:33Z
dc.date.available2019-08-23T10:48:33Z
dc.date.issued2018-10-01en_US
dc.description.abstract© 2018 Elsevier B.V. In flow analysis, such as flow injection analysis, liquid lens is formed at the boundary between two adjacent liquid media which have different refractive indices. Light refraction at the liquid interface gives the so-called 'schlieren signal’. Schlieren effect is both concentration-dependent and temperature-dependent. In this work, the schlieren signal from temperature difference was quantitatively investigated for application in enthalpimetric measurement. The schlieren phenomena was then exploited for chemical analysis. A thermal insulated single flow line manifold was constructed using deionized water at 23 °C as the carrier. Deionized water at various temperatures in the range of 5–85 °C was injected into the carrier flow. A correlation between the schlieren signal and sample temperature was observed. A heat exchanger unit (HEU), consisting of a small volume glass-reaction chamber with a surrounding water jacket, was constructed. The unit was thermally insulated in a double layer cylindrical PVC unit. For demonstrating the applicability of temperature-dependent schlieren effect in chemical analysis, the exothermic oxidation reaction between acid dichromate and ethanol or ascorbic acid was employed with heat transferring to the surrounding water layer. When an aliquot of water from the HEU is injected into the constant temperature flow line the observed schlieren signal was dependent on the analyte concentration. Linear calibration (r2 > 0.99) were obtained covering the concentration range of ethanol and ascorbic acid as found in samples. The developed flow system provides good precision (RSD < 5%) with sample throughput of 4 sample h−1. The system were applied to the determination of ethanol in Thai white spirit and ascorbic acid in vitamin C tablets, respectively. The quantitative results obtained from the schlieren method were in agreement with the comparative methods.en_US
dc.identifier.citationTalanta. Vol.188, (2018), 74-80en_US
dc.identifier.doi10.1016/j.talanta.2018.05.055en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-85047274682en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/45474
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85047274682&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleTemperature-dependent schlieren effect in liquid flow for chemical analysisen_US
dc.typeArticleen_US