Publication: Development of an amperometric immunosensor for the determination of methamphetamine in urine
| dc.contributor.author | Kavinyanee Luangaram | en_US |
| dc.contributor.author | Dolurdee Boonsua | en_US |
| dc.contributor.author | Sarisak Soontornchai | en_US |
| dc.contributor.author | Chamras Promptmas | en_US |
| dc.contributor.other | Mahidol University | en_US |
| dc.contributor.other | Sukhothai Thammatirat Open University | en_US |
| dc.date.accessioned | 2018-07-24T02:56:04Z | |
| dc.date.available | 2018-07-24T02:56:04Z | |
| dc.date.issued | 2002-12-01 | en_US |
| dc.description.abstract | An amperometric immunosensor in the competitive format was developed for the detection of methamphetamine in urine. The electrodes consisted of carbon paste and Ag/AgCl screen printed on heat sealing film, respectively, and of monoclonal lanti-methamphetamine antibody as the biorecognition element. Optimum amounts of methamphetamine-N-bovine serum albumin conjugate, monoclonal antibody and alkaline phosphatase-goat anti-mouse immunoglobulin G were 20, 10 ng and 1:10,000 dilution in 10 μl each, respectively. Methamphetamine was detected by the conversion of p-aminophenyl phosphate to electroactive p-aminophenol in the range of 200 ng/ml (lower detection limit) to 1,500 ng/ml methamphetamine in a nearly linear dose response curve. Within amphetamine concentrations of 0-1,500 ng/ml cross-reaction with methamphethamine was not observed. Working with urine samples spiked with methamphetamine, the accuracy and precision of the assay were 91.5-104.4% and 15.8-24.4%, respectively. This is a proof of concept in the clinical perspective for an amperometric immunosensor whose electrodes are amenable to future mass production. | en_US |
| dc.identifier.citation | Biocatalysis and Biotransformation. Vol.20, No.6 (2002), 397-403 | en_US |
| dc.identifier.doi | 10.1080/1024242021000058685 | en_US |
| dc.identifier.issn | 10242422 | en_US |
| dc.identifier.other | 2-s2.0-0036904456 | en_US |
| dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/20018 | |
| dc.rights | Mahidol University | en_US |
| dc.rights.holder | SCOPUS | en_US |
| dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0036904456&origin=inward | en_US |
| dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
| dc.subject | Chemical Engineering | en_US |
| dc.title | Development of an amperometric immunosensor for the determination of methamphetamine in urine | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0036904456&origin=inward | en_US |