Publication: Assessment of the accuracy and reliability of cephsmile v.2 in cephalograms and model measurements
dc.contributor.author | Orrathai Watcharinporn | en_US |
dc.contributor.author | Surachai Dechkunakorn | en_US |
dc.contributor.author | Niwat Anuwongnukroh | en_US |
dc.contributor.author | Chanjira Sinthanayothin | en_US |
dc.contributor.author | Peerapong Santiwong | en_US |
dc.contributor.author | Wisarut Bholsithi | en_US |
dc.contributor.author | Wanna Suchato | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Thailand National Electronics and Computer Technology Center | en_US |
dc.date.accessioned | 2018-06-11T04:48:38Z | |
dc.date.available | 2018-06-11T04:48:38Z | |
dc.date.issued | 2012-02-20 | en_US |
dc.description.abstract | Objective: The study compared the measurement values from lateral cephalometric analysis, postero-anterior cephalometric analysis and study models between CephSmile version 2.0 and hand-traced method. Materials and Methods: Thirty sets of digital lateral, postero-anterior cephalograms and plaster models were selected randomly, uploaded and measured with CephSmile version 2.0 Program. All dental measurements were compared with manual measurements. Manual cephalometic measurements were obtained with a cepholomatic protractor and model measurements with vernier calipers. Both groups were assessed for accuracy and reliability. Mean and SD were calculated using SPSS version 11.0. Results: All CephSmile and hand-traced radiograph coefficients of variation were less than 0.10 suggesting high interexaminer reliability. No significant differences were found comparing lateral cephalograms, postero-anterior cephalograms, and plaster models between manual measurements and CephSmile Program version 2.0. Conclusion: CephSmile Software version 2.0 is as accurate and reliable as manual measurements for cephalometric analysis in orthodontic clinical treatment and planning. © 2012 Springer-Verlag GmbH. | en_US |
dc.identifier.citation | Lecture Notes in Electrical Engineering. Vol.143 LNEE, No.VOL. 1 (2012), 413-422 | en_US |
dc.identifier.doi | 10.1007/978-3-642-27323-0_52 | en_US |
dc.identifier.issn | 18761119 | en_US |
dc.identifier.issn | 18761100 | en_US |
dc.identifier.other | 2-s2.0-84856831946 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/14163 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84856831946&origin=inward | en_US |
dc.subject | Engineering | en_US |
dc.title | Assessment of the accuracy and reliability of cephsmile v.2 in cephalograms and model measurements | en_US |
dc.type | Conference Paper | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84856831946&origin=inward | en_US |