Publication:
Assessment of the accuracy and reliability of cephsmile v.2 in cephalograms and model measurements

dc.contributor.authorOrrathai Watcharinpornen_US
dc.contributor.authorSurachai Dechkunakornen_US
dc.contributor.authorNiwat Anuwongnukrohen_US
dc.contributor.authorChanjira Sinthanayothinen_US
dc.contributor.authorPeerapong Santiwongen_US
dc.contributor.authorWisarut Bholsithien_US
dc.contributor.authorWanna Suchatoen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherThailand National Electronics and Computer Technology Centeren_US
dc.date.accessioned2018-06-11T04:48:38Z
dc.date.available2018-06-11T04:48:38Z
dc.date.issued2012-02-20en_US
dc.description.abstractObjective: The study compared the measurement values from lateral cephalometric analysis, postero-anterior cephalometric analysis and study models between CephSmile version 2.0 and hand-traced method. Materials and Methods: Thirty sets of digital lateral, postero-anterior cephalograms and plaster models were selected randomly, uploaded and measured with CephSmile version 2.0 Program. All dental measurements were compared with manual measurements. Manual cephalometic measurements were obtained with a cepholomatic protractor and model measurements with vernier calipers. Both groups were assessed for accuracy and reliability. Mean and SD were calculated using SPSS version 11.0. Results: All CephSmile and hand-traced radiograph coefficients of variation were less than 0.10 suggesting high interexaminer reliability. No significant differences were found comparing lateral cephalograms, postero-anterior cephalograms, and plaster models between manual measurements and CephSmile Program version 2.0. Conclusion: CephSmile Software version 2.0 is as accurate and reliable as manual measurements for cephalometric analysis in orthodontic clinical treatment and planning. © 2012 Springer-Verlag GmbH.en_US
dc.identifier.citationLecture Notes in Electrical Engineering. Vol.143 LNEE, No.VOL. 1 (2012), 413-422en_US
dc.identifier.doi10.1007/978-3-642-27323-0_52en_US
dc.identifier.issn18761119en_US
dc.identifier.issn18761100en_US
dc.identifier.other2-s2.0-84856831946en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/14163
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84856831946&origin=inwarden_US
dc.subjectEngineeringen_US
dc.titleAssessment of the accuracy and reliability of cephsmile v.2 in cephalograms and model measurementsen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84856831946&origin=inwarden_US

Files

Collections