Publication: Development and Validation of Liquid Chromatography/Tandem Mass Spectrometry Analysis for Therapeutic Drug Monitoring of Risperidone and 9-Hydroxyrisperidone in Pediatric Patients with Autism Spectrum Disorders
dc.contributor.author | Natchaya Vanwong | en_US |
dc.contributor.author | Santirat Prommas | en_US |
dc.contributor.author | Apichaya Puangpetch | en_US |
dc.contributor.author | Yaowaluck Hongkaew | en_US |
dc.contributor.author | Nopadol Nuntamool | en_US |
dc.contributor.author | Chalitpol Na Nakorn | en_US |
dc.contributor.author | Nattawat Ngamsamut | en_US |
dc.contributor.author | Penkhae Limsila | en_US |
dc.contributor.author | Chonlaphat Sukasem | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Faculty of Medicine, Ramathibodi Hospital, Mahidol University | en_US |
dc.contributor.other | Thailand Ministry of Public Health | en_US |
dc.date.accessioned | 2018-12-11T02:07:22Z | |
dc.date.accessioned | 2019-03-14T08:03:47Z | |
dc.date.available | 2018-12-11T02:07:22Z | |
dc.date.available | 2019-03-14T08:03:47Z | |
dc.date.issued | 2016-11-01 | en_US |
dc.description.abstract | © 2016 Wiley Periodicals, Inc. Background: Risperidone (RIS) is a widely used atypical antipsychotic drug. We developed and validated a sensitive and accurate LC-MS/MS method, which requires a small-volume of plasma and small-volume injection for measurement of RIS levels in ASD pediatric patients. We also investigated the relationship between RIS levels and RIS dosages, including prolactin levels. Method: Blood samples were processed by protein precipitation extraction. Only 1 μl of sample was injected. Plasma samples were separated on a C18 column (4.6 cm × 50 mm; 1.8 μm particle size). Detection was by MS-MS with an analytical run time of 6 min. Results: The inter-day accuracy of RIS was 101.33–107.68% and 95.24–103.67% for 9-OH-RIS. The inter-day precision of RIS was ≤7.27% CV and ≤7.41% CV for 9-OH-RIS. The extraction recovery of RIS and 9-OH-RIS were 95.01 ± 7.31–112.62 ± 7.50% and 90.27 ± 11.15–114.00 ± 10.35%, respectively. This method was applied in the therapeutic drug monitoring of ASD pediatric patients. Higher RIS dosage has a tendency to produce higher RIS plasma levels. The high RIS plasma levels have a tendency to produce hyperprolactinemia. Conclusion: The determination of RIS in individual patients might be clinically useful for monitoring and prediction of treatment response. | en_US |
dc.identifier.citation | Journal of Clinical Laboratory Analysis. Vol.30, No.6 (2016), 1236-1246 | en_US |
dc.identifier.doi | 10.1002/jcla.22009 | en_US |
dc.identifier.issn | 10982825 | en_US |
dc.identifier.issn | 08878013 | en_US |
dc.identifier.other | 2-s2.0-84977588619 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.14594/42758 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84977588619&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Health Professions | en_US |
dc.subject | Medicine | en_US |
dc.title | Development and Validation of Liquid Chromatography/Tandem Mass Spectrometry Analysis for Therapeutic Drug Monitoring of Risperidone and 9-Hydroxyrisperidone in Pediatric Patients with Autism Spectrum Disorders | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84977588619&origin=inward | en_US |