Publication:
Stopped-in-loop flow analysis system for successive determination of trace vanadium and iron in drinking water using their catalytic reactions

dc.contributor.authorAlejandro Ayala Quezadaen_US
dc.contributor.authorKeisuke Oharaen_US
dc.contributor.authorNuanlaor Ratanawimarnwongen_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.authorHiroya Murakamien_US
dc.contributor.authorNorio Teshimaen_US
dc.contributor.authorTadao Sakaien_US
dc.contributor.otherAichi Institute of Technologyen_US
dc.contributor.otherSrinakharinwirot Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-11-23T09:40:41Z
dc.date.available2018-11-23T09:40:41Z
dc.date.issued2015-07-22en_US
dc.description.abstract© 2015 Elsevier B.V. All rights reserved. An automated stopped-in-loop flow analysis (SILFA) system is proposed for the successive catalytic determination of vanadium and iron. The determination of vanadium was based on the p-anisidine oxidation by potassium bromate in the presence of Tiron as an activator to form a reddish dye, which has an absorption maximum at 510 nm. The selectivity of the vanadium determination was greatly improved by adding diphosphate as a masking agent of iron. For the iron determination, an iron-catalyzed oxidative reaction of p-anisidine by hydrogen peroxide with 1,10-phenanthroline as an activator to produce a reddish dye (510 nm) was employed. The SILFA system consisted of two peristaltic pumps, two six-port injection valves, a four-port selection valve, a heater device, a spectrophotometric detector and a data acquisition device. One six-port injection valve was used for the isolation of a mixed solution of standard/sample and reagent to promote each catalytic reaction, and another six-port injection valve was used for switching the reagent for vanadium or iron to achieve selective determination of each analyte. The above mentioned four-port selection valve was used to select standard solutions or sample. These three valves and the two peristaltic pumps were controlled by a built-in programmable logic controller in a touchscreen controller. The obtained results showed that the proposed SILFA monitoring system constituted an effective approach for the selective determination of vanadium and iron. The limits of detection, 0.052 and 0.55 μg L-1, were obtained for vanadium and iron, respectively. The proposed system was successfully applied to drinking water samples without any preconcentration procedures.en_US
dc.identifier.citationTalanta. Vol.144, (2015), 844-850en_US
dc.identifier.doi10.1016/j.talanta.2015.07.006en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-84937598809en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/35422
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84937598809&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.titleStopped-in-loop flow analysis system for successive determination of trace vanadium and iron in drinking water using their catalytic reactionsen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84937598809&origin=inwarden_US

Files

Collections