Publication:
Metal artifact reduction and image quality evaluation of lumbar spine CT images using metal sinogram segmentation

dc.contributor.authorTitipong Kaewleken_US
dc.contributor.authorDiew Koolpirucken_US
dc.contributor.authorSaowapak Thongvigitmaneeen_US
dc.contributor.authorManus Mongkolsuken_US
dc.contributor.authorSastrawut Thammakittiphanen_US
dc.contributor.authorSiri On Tritrakarnen_US
dc.contributor.authorPipat Chiewviten_US
dc.contributor.otherKing Mongkuts University of Technology Thonburien_US
dc.contributor.otherThailand National Electronics and Computer Technology Centeren_US
dc.contributor.otherRangsit Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-11-23T10:05:13Z
dc.date.available2018-11-23T10:05:13Z
dc.date.issued2015-12-17en_US
dc.description.abstract© 2015 - IOS Press and the authors. Metal artifacts often appear in the images of computed tomography (CT) imaging. In the case of lumbar spine CT images, artifacts disturb the images of critical organs. These artifacts can affect the diagnosis, treatment, and follow up care of the patient. One approach to metal artifact reduction is the sinogram completion method. A mixed-variable thresholding (MixVT) technique to identify the suitable metal sinogram is proposed. This technique consists of four steps: 1) identify the metal objects in the image by using k-mean clustering with the soft cluster assignment, 2) transform the image by separating it into two sinograms, one of which is the sinogram of the metal object, with the surrounding tissue shown in the second sinogram. The boundary of the metal sinogram is then found by the MixVT technique, 3) estimate the new value of the missing data in the metal sinogram by linear interpolation from the surrounding tissue sinogram, 4) reconstruct a modified sinogram by using filtered back-projection and complete the image by adding back the image of the metal object into the reconstructed image to form the complete image. The quantitative and clinical image quality evaluation of our proposed technique demonstrated a significant improvement in image clarity and detail, which enhances the effectiveness of diagnosis and treatment.en_US
dc.identifier.citationJournal of X-Ray Science and Technology. Vol.23, No.6 (2015), 649-666en_US
dc.identifier.doi10.3233/XST-150518en_US
dc.identifier.issn08953996en_US
dc.identifier.other2-s2.0-84952942984en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/35901
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84952942984&origin=inwarden_US
dc.subjectEngineeringen_US
dc.subjectMedicineen_US
dc.titleMetal artifact reduction and image quality evaluation of lumbar spine CT images using metal sinogram segmentationen_US
dc.typeArticleen_US