Publication: Flow-injection determination of iodide ion in nuclear emergency tablets, using boron-doped diamond thin film electrode
dc.contributor.author | O. Chailapakul | en_US |
dc.contributor.author | M. Amatatongchai | en_US |
dc.contributor.author | P. Wilairat | en_US |
dc.contributor.author | K. Grudpan | en_US |
dc.contributor.author | D. Nacapricha | en_US |
dc.contributor.other | Chulalongkorn University | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Chiang Mai University | en_US |
dc.date.accessioned | 2018-07-24T03:39:40Z | |
dc.date.available | 2018-07-24T03:39:40Z | |
dc.date.issued | 2004-12-15 | en_US |
dc.description.abstract | The electrochemical determination of iodide was studied at boron-doped diamond thin film electrodes (BDD) using cyclic voltammetry (CV) and flow-injection (FI) analysis, with amperometric detection. Cyclic voltammetry of iodide was conducted in a phosphate buffer pH 5. Experiments were performed using glassy carbon (GC) electrode as a comparison. Well-defined oxidation waves of the quasi-reversible cyclic voltammograms were observed at both electrodes. Voltammetric signal-to-background ratios (S/B) were comparable. However, the GC electrode gives much greater in the background current as usual. The potential sweep rate dependence exhibited that the peak current of iodide oxidation at 1 mM varied linearly (r2= 0.998) with the square root of the scan rate, from 0.01 to 0.30 V s-1. This result indicates that the reaction is a diffusion-controlled process with negligible adsorption on BDD surface, at this iodide concentration. Results of the flow-injection analysis show a highly reproducible amperometric response. The linear working range was observed up to 200 μM (r2= 0.999). The detection limit, as low as 0.01 μM (3σ of blank), was obtained. This method was successfully applied for quantification of iodide contents in nuclear emergency tablets. © 2004 Elsevier B.V. All rights reserved. | en_US |
dc.identifier.citation | Talanta. Vol.64, No.5 SPEC. ISS. (2004), 1253-1258 | en_US |
dc.identifier.doi | 10.1016/j.talanta.2004.04.023 | en_US |
dc.identifier.issn | 00399140 | en_US |
dc.identifier.other | 2-s2.0-7044229330 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/21261 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=7044229330&origin=inward | en_US |
dc.subject | Chemistry | en_US |
dc.title | Flow-injection determination of iodide ion in nuclear emergency tablets, using boron-doped diamond thin film electrode | en_US |
dc.type | Conference Paper | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=7044229330&origin=inward | en_US |