Publication:
Flow-injection determination of iodide ion in nuclear emergency tablets, using boron-doped diamond thin film electrode

dc.contributor.authorO. Chailapakulen_US
dc.contributor.authorM. Amatatongchaien_US
dc.contributor.authorP. Wilairaten_US
dc.contributor.authorK. Grudpanen_US
dc.contributor.authorD. Nacaprichaen_US
dc.contributor.otherChulalongkorn Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherChiang Mai Universityen_US
dc.date.accessioned2018-07-24T03:39:40Z
dc.date.available2018-07-24T03:39:40Z
dc.date.issued2004-12-15en_US
dc.description.abstractThe electrochemical determination of iodide was studied at boron-doped diamond thin film electrodes (BDD) using cyclic voltammetry (CV) and flow-injection (FI) analysis, with amperometric detection. Cyclic voltammetry of iodide was conducted in a phosphate buffer pH 5. Experiments were performed using glassy carbon (GC) electrode as a comparison. Well-defined oxidation waves of the quasi-reversible cyclic voltammograms were observed at both electrodes. Voltammetric signal-to-background ratios (S/B) were comparable. However, the GC electrode gives much greater in the background current as usual. The potential sweep rate dependence exhibited that the peak current of iodide oxidation at 1 mM varied linearly (r2= 0.998) with the square root of the scan rate, from 0.01 to 0.30 V s-1. This result indicates that the reaction is a diffusion-controlled process with negligible adsorption on BDD surface, at this iodide concentration. Results of the flow-injection analysis show a highly reproducible amperometric response. The linear working range was observed up to 200 μM (r2= 0.999). The detection limit, as low as 0.01 μM (3σ of blank), was obtained. This method was successfully applied for quantification of iodide contents in nuclear emergency tablets. © 2004 Elsevier B.V. All rights reserved.en_US
dc.identifier.citationTalanta. Vol.64, No.5 SPEC. ISS. (2004), 1253-1258en_US
dc.identifier.doi10.1016/j.talanta.2004.04.023en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-7044229330en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/21261
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=7044229330&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleFlow-injection determination of iodide ion in nuclear emergency tablets, using boron-doped diamond thin film electrodeen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=7044229330&origin=inwarden_US

Files