Publication:
Diurnal variation of higher order aberrations in human eyes

dc.contributor.authorSabong Srivannaboonen_US
dc.contributor.authorDan Z. Reinsteinen_US
dc.contributor.authorTimothy J. Archeren_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherKing's College Londonen_US
dc.contributor.otherWeill Cornell Medical Collegeen_US
dc.date.accessioned2018-08-24T02:06:49Z
dc.date.available2018-08-24T02:06:49Z
dc.date.issued2007-05-01en_US
dc.description.abstractPURPOSE: To evaluate diumal variation of higher order aberrations in human eyes. METHODS: A prospective study of 20 myopic eyes was performed. Cycloplegic aberrometry (Zywave) and refraction were measured at 2-hour intervals for five time points beginning at 10:00 AM. Changes in measured magnitude for third and fourth order Zernike coefficients were compared over time. Analysis of variance (ANOVA) was performed to test for statistically significant differences across time points for each Zernike coefficient. A separate prospective study was performed of 11 myopic eyes to determine and compare diurnal variation with the repeatability coefficient of individual Zernike coefficients measured using the Zywave aberrometer. RESULTS: Mean refraction was -0.75±1.25 diopters (D) sphere and -0.57±0.43 D cylinder. No statistically significant change (ANOVA) was noted over the period of observation for any individual Zernike coefficients. Only Z3-3(vertical trefoil) showed an average increase of 0.029 μm (P=.98) towards the end of the day; however, this trend was not statistically significant. The standard deviation of individual Zernike coefficients ranged from 0.035 μm (Z44) to 0.165 μm (Z3-1). CONCLUSIONS: No statistically significant diurnal variation of higher order aberrations was measured by Zywave aberrometer. The trend of Z3-3increasing later in the day was most likely a Zywave measurement error artifact.en_US
dc.identifier.citationJournal of Refractive Surgery. Vol.23, No.5 (2007), 442-446en_US
dc.identifier.issn1081597Xen_US
dc.identifier.other2-s2.0-34248572941en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/24907
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34248572941&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleDiurnal variation of higher order aberrations in human eyesen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34248572941&origin=inwarden_US

Files

Collections