Publication:
Matrix removal before inductively coupled plasma spectrometric detection: Another capability of flow field-flow fractionation

dc.contributor.authorSupharart Sangsawongen_US
dc.contributor.authorJuwadee Shiowatanaen_US
dc.contributor.authorAtitaya Siripinyanonden_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-08-20T06:54:46Z
dc.date.available2018-08-20T06:54:46Z
dc.date.issued2006-11-06en_US
dc.description.abstractA modified flow field-flow fractionation (FlFFF) configuration was investigated for its matrix removal capability before inductively coupled plasma optical emission spectrometric (ICP-OES) detection. Poly(ethylene imine) (PEI) having a molecular weight of 25000 Da was added to test solutions (buffered at pH 9) to form complexes with analyte elements (Ag, Cd, Co, Cu, Hg, Ni, Pb and Zn) but not with the matrix elements (Ca, K, Mg and Na). With the use of a poly(ether sulfone) membrane having a 1000 Da molecular weight cut-off inside the FlFFF channel, matrix elements were removed by filtering off through the membrane, whereas the PEI-analyte complexes remained in the channel and were subsequently eluted and detected. Two approaches, i.e., cross flow matrix removal (CFM) and opposing flow matrix removal-analyte preconcentration (OFM), were evaluated for matrix removal and matrix removal with simultaneous preconcentration, respectively. With the FlFFF/CFM approach, the signal intensities of matrix elements were reduced by approximately 80-90% while those of analyte elements were only slightly reduced (∼20%). With the FlFFF/OFM approach, an unlimited sample volume can be introduced into the FlFFF channel with an elution volume of approximately 1 ml, leading to analyte preconcentration. © The Royal Society of Chemistry 2006.en_US
dc.identifier.citationJournal of Analytical Atomic Spectrometry. Vol.21, No.11 (2006), 1336-1339en_US
dc.identifier.doi10.1039/b607204fen_US
dc.identifier.issn13645544en_US
dc.identifier.issn02679477en_US
dc.identifier.other2-s2.0-33750471617en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/23142
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33750471617&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleMatrix removal before inductively coupled plasma spectrometric detection: Another capability of flow field-flow fractionationen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33750471617&origin=inwarden_US

Files

Collections