Publication:
Quantifying step count and oxygen consumption with portable technology during the 2-minute walk test in people with lower limb amputation

dc.contributor.authorJohn D. Smithen_US
dc.contributor.authorGary Guerraen_US
dc.contributor.otherSiriraj Hospitalen_US
dc.contributor.otherTexas A&M University-San Antonioen_US
dc.date.accessioned2022-08-04T08:11:14Z
dc.date.available2022-08-04T08:11:14Z
dc.date.issued2021-03-02en_US
dc.description.abstractStep counts and oxygen consumption have yet to be reported during the 2-min walk test (2MWT) test in persons with lower-limb amputations (LLA). The purpose of this study was to determine step counts and oxygen consumption during the 2MWT in LLA. Thirty-five men and women walked for two minutes as quickly as possible while wearing activity monitors (ActiGraph Link on the wrist (LW) and ankle (LA), Garmin vivofit®3 on the wrist (VW) and ankle (VA), and a modus StepWatch on the ankle (SA), and a portable oxygen analyzer. The StepWatch on the ankle (SA) and the vivofit3 on the wrist (VW) had the least error and best accuracy of the activity monitors studied. While there were no significant differences in distance walked, oxygen consumption (VO2) or heart rate (HR) between sexes or level of amputation (p > 0.05), females took significantly more steps than males (p = 0.034), and those with unilateral transfemoral amputations took significantly fewer steps than those with unilateral transtibial amputations (p = 0.023). The VW and SA provided the most accurate step counts among the activity monitors and were not significantly different than hand counts. Oxygen consumption for all participants during the 2MWT was 8.9 ± 2.9 mL/kg/min, which is lower than moderate-intensity activity. While some may argue that steady-state activity has not yet been reached in the 2MWT, it may also be possible participants are not walking as fast as they can, thereby misclassifying their performance to a lower standard.en_US
dc.identifier.citationSensors. Vol.21, No.6 (2021), 1-13en_US
dc.identifier.doi10.3390/s21062080en_US
dc.identifier.issn14248220en_US
dc.identifier.other2-s2.0-85102560142en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/76250
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85102560142&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.subjectComputer Scienceen_US
dc.subjectEngineeringen_US
dc.subjectPhysics and Astronomyen_US
dc.titleQuantifying step count and oxygen consumption with portable technology during the 2-minute walk test in people with lower limb amputationen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85102560142&origin=inwarden_US

Files

Collections