Publication:
Microtensile bond strength of repaired indirect resin composite

dc.contributor.authorPorntida Visuttiwattanakornen_US
dc.contributor.authorKallaya Suputtamongkolen_US
dc.contributor.authorDuangjai Angkoonsiten_US
dc.contributor.authorSunattha Kaewthongen_US
dc.contributor.authorPiyanan Charoonananen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-12-21T07:25:52Z
dc.date.accessioned2019-03-14T08:03:29Z
dc.date.available2018-12-21T07:25:52Z
dc.date.available2019-03-14T08:03:29Z
dc.date.issued2017-01-01en_US
dc.description.abstract© 2017 The Korean Academy of Prosthodontics. PURPOSE. The objective of this study was to investigate the effect of surface treatments on microtensile bond strengths (MTBSs) of two types of indirect resin composites bonded to a conventional direct resin composite. MATERIALS AND METHODS. Indirect resin composite blocks of Ceramage and SR Nexco were prepared in a plastic mold having a dimension of 10 × 10 × 4 mm. These composite blocks were divided into three groups according to their surface treatments: Group1: Sandblast (SB); Group2: Sandblast and ultrasonically clean (SB+ UL); Group3: Sandblast plus silane (SB+SI). After bonding with direct resin composite, indirect-direct resin composite blocks were kept in distilled water for 24 hours at 37°C and cut into microbars with the dimension of 1 × 1 × 8 mm. Microbar specimens (n = 40 per group) were loaded using a universal testing machine. Failure modes and compositions were evaluated by SEM. The statistical analyses of MTBS were performed by two-way ANOVA and Dunnett's test at α =.05. RESULTS. Surface treatments and brands had effects on the MTBS without an interaction between these two factors. For SR Nexco, the MTBSs of SB and SB+SI group were significantly higher than that of SB+UL. For Ceramage, the MTBSs of SB and SB+SI were significantly higher than that of SB+UL. The mean MTBS of the Ceramage specimens was significantly higher than that of SR Nexco for all surface treatments. CONCLUSION. Sandblasting with or without silane application could improve the bond strengths of repaired indirect resin composites to a conventional direct resin composite.en_US
dc.identifier.citationJournal of Advanced Prosthodontics. Vol.9, No.1 (2017), 38-44en_US
dc.identifier.doi10.4047/jap.2017.9.1.38en_US
dc.identifier.issn20057814en_US
dc.identifier.issn20057806en_US
dc.identifier.other2-s2.0-85013943386en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/42441
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85013943386&origin=inwarden_US
dc.subjectDentistryen_US
dc.titleMicrotensile bond strength of repaired indirect resin compositeen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85013943386&origin=inwarden_US

Files

Collections