Publication:
User‐defined serum aspartate and alanine aminotransferase, cholesterol, triglycerides, urea, and uric acid for the Beckman synchron CX 4/5 using Ames Sera‐Pak reagents

dc.contributor.authorPorntip H. Lolekhaen_US
dc.contributor.authorPornpen Nitipaichiten_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-08-10T08:44:24Z
dc.date.available2018-08-10T08:44:24Z
dc.date.issued1992-01-01en_US
dc.description.abstractBeckman aspartate aminotransferase (AST), alanine aminotransferase (ALT), cholesterol, triglycerides, urea, and uric acid liquid Reagents for Synchron CX 4/5 (48, 48, 25, 60, 26, and 30 cents US/test, respectively) are expensive. We have established our own methods for serum AST, ALT, cholesterol, triglycerides, urea, and uric acid (6, 6, 5, 12, 13, and 6 cents US/test, respectively) using Ames Sera‐Pak reagents. Linearity of our AST, ALT, cholesterol, triglycerides, urea, and uric acid methods were either similar to or higher than the Beckman mehtods. The within run and day‐to‐day run precisions were acceptable. Recovery of our AST, ALT, cholesterol, triglycerides, urea, and uric acid wee excellent. Our results for AST, ALT, cholesterol, triglycerides, urea, and uric acid correlated well with the Beckman results. Bilirubin (340.8 μmol/L) did not significantly interfere on our AST, ALT, cholesterol, triglycerides, and urea, while its concentrations of 165.8 μmol/L started giving negative interference on uric acid. Turbidity (2+) did not interfere significantly on our AST and ALT but started giving positive interference on cholesterol, triglycerides, urea, and uric acid. Hemolysis (2+) gave positive interference on our cholesterol, triglycerides, urea, and uric acid. Stability of Ames Sera‐Pak working reagents was at least 30 days for AST, ALT, urea, and uric acid and 40 days for cholesterol and triglycerides. © 1992 Wiley‐Liss, Inc. Copyright © 1992 Wiley Periodicals, Inc., A Wiley Companyen_US
dc.identifier.citationJournal of Clinical Laboratory Analysis. Vol.6, No.5 (1992), 245-256en_US
dc.identifier.doi10.1002/jcla.1860060502en_US
dc.identifier.issn10982825en_US
dc.identifier.issn08878013en_US
dc.identifier.other2-s2.0-0026669984en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/22272
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0026669984&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectHealth Professionsen_US
dc.subjectMedicineen_US
dc.titleUser‐defined serum aspartate and alanine aminotransferase, cholesterol, triglycerides, urea, and uric acid for the Beckman synchron CX 4/5 using Ames Sera‐Pak reagentsen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0026669984&origin=inwarden_US

Files