Publication:
A Pilot Study of Small-Diameter One-Piece Ceramic mp Placed in Anterior Regions: Clinical and Esthetic Outcomes at 1-Year Follow-up

dc.contributor.authorChatchai Kunavisaruten_US
dc.contributor.authorLeerawan Buranaianyakulen_US
dc.contributor.authorJira Kitisubkanchanaen_US
dc.contributor.authorPiyapanna Pumpaluken_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2020-12-28T05:01:31Z
dc.date.available2020-12-28T05:01:31Z
dc.date.issued2020-10-01en_US
dc.description.abstract©2020 by Quintessence Publishing Co Inc. Purpose:The aim of this study was to evaluate the clinical, esthetic, and patient-reported outcomes of one-piece zirconia implants placed in incisal areas using digital surgical templates after 1 year of follow-up. Materials and Methods: Patients who had lost an anterior tooth received a 3.3-mm-diameter zirconia implant placed by computer-guided surgery. Implant survival and soft tissue conditions were assessed periodically 1 week, 3 months, 6 months, and 1 year after loading. Standardized radiographs were taken at definitive prosthesis insertion and 1 year postloading to evaluate peri-implant bone loss. Additionally, the esthetic outcomes and patient-reported outcomes were also investigated. Results: Twenty zirconia implants were placed in 20 patients with no implants lost, resulting in 100% survival rates. A minor change in the mean marginal bone level (0.14 ± 0.87 mm) was found between definitive prosthetic loading and 12 months later. Peri-implant soft tissue remained stable throughout the observation period. The mean Pink Esthetic Score and White Esthetic Score were 12.05 and 8.60, respectively, while the mean Gingival Papilla Index scores were 1.55 at the mesial papilla and 1.65 at the distal papilla at the 1-year follow-up. The mean visual analog scale scores for patient perception of the overall process, speech, mastication, and esthetics were 93.3 ± 7.8, 95.1 ± 5.3, 93.6 ± 7.6, and 94.5 ± 6.2 mm, respectively. Conclusion: For the 1-year results, 3.3-mm-diameter one-piece ceramic implants placed by computer-guided surgery showed favorable clinical performances with no failure when used for single-tooth replacement in anterior regions. Int J Oral Maxillofac Implants 2020;35:965-973. doi: 10.11607/jomi.8308en_US
dc.format.mimetypevideo/youtube
dc.identifier.citationInternational Journal of Oral and Maxillofacial Implants. Vol.35, No.5 (2020), 965-973en_US
dc.identifier.doi10.11607/jomi.8308en_US
dc.identifier.issn19424434en_US
dc.identifier.issn08822786en_US
dc.identifier.other2-s2.0-85092386319en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/60453
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85092386319&origin=inwarden_US
dc.subjectDentistryen_US
dc.titleA Pilot Study of Small-Diameter One-Piece Ceramic mp Placed in Anterior Regions: Clinical and Esthetic Outcomes at 1-Year Follow-upen_US
dc.typeArticleen_US
dspace.entity.typePublication
mediaObject.contentUrlhttps://www.youtube.com/watch?v=PFi8Y0KJ-yA
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85092386319&origin=inwarden_US

Files

Collections