Publication:
Comparison of the effectiveness of endotracheal tube holder with the conventional method in a manikin model

dc.contributor.authorKarn Suttapaniten_US
dc.contributor.authorChaiyaporn Yuksenen_US
dc.contributor.authorKasamon Aramvanitchen_US
dc.contributor.authorThitapohn Meemongkolen_US
dc.contributor.authorArnon Chandechen_US
dc.contributor.authorBenjamat Songkatheeen_US
dc.contributor.authorPromphet Nuanpromen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2020-11-18T09:58:52Z
dc.date.available2020-11-18T09:58:52Z
dc.date.issued2020-10-01en_US
dc.description.abstract© 2020 Turkish Journal of Emergency Medicine | Published by Wolters Kluwer-Medknow. OBJECTIVES: Endotracheal tube (ETT) displacement occurs by improper fixation. To fix an ETT, many types of fixation tools are employed. Thomas tube holder is one of the fixation tools widely used in many countries. This study aims to compare the ETT fixation using the Thomas tube holder with the conventional method (adhesive tape) in a mannequin model. METHODS: The fixation tools were random, using the box of six randomizes to Thomas tube holder and conventional method. After fixation, the mannequin model was being logged roll, chest compression by automated chest compression machine, and transported by the paramedic. The time to ETT fixation and displacements were recorded. RESULTS: The mean time (standard deviation) to fixate an ETT was shorter (33.0 s [7.3]) with a Thomas tube holder compared to adhesive tape (52.6 s [7.3], P < 0.001). The number and proportion of the ETT displacements were significantly less with Thomas tube holder compared to adhesive tape during log roll (16, 35.6% vs. 29, 64.4%, P = 0.011), chest compression with automated machine (23, 51.1% vs. 37, 82.2%, P = 0.003), and transport (26, 57.8% vs. 40, 88.9%, P = 0.002). CONCLUSION: The Thomas tube holder is more effective than adhesive tape in preventing ETT displacement in a mannequin subjected to log roll, chest compressions, and transportation.en_US
dc.identifier.citationTurkish Journal of Emergency Medicine. Vol.20, No.4 (2020), 175-179en_US
dc.identifier.doi10.4103/2452-2473.297470en_US
dc.identifier.issn24522473en_US
dc.identifier.other2-s2.0-85093839584en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/60051
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85093839584&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleComparison of the effectiveness of endotracheal tube holder with the conventional method in a manikin modelen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85093839584&origin=inwarden_US

Files