Publication: Assessment and comparative analysis of a rapid diagnostic test (Tubex<sup>®</sup>) for the diagnosis of typhoid fever among hospitalized children in rural Tanzania
Issued Date
2011-05-24
Resource Type
ISSN
14712334
Other identifier(s)
2-s2.0-79956260663
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Bibliographic Citation
BMC Infectious Diseases. Vol.11, (2011)
Suggested Citation
Benedikt Ley, Kamala Thriemer, Shaali M. Ame, George M. Mtove, Lorenz von Seidlein, Ben Amos, Ilse C E Hendriksen, Abraham Mwambuli, Aikande Shoo, Deok R. Kim, Leon R. Ochiai, Michael Favorov, John D. Clemens, Harald Wilfing, Jacqueline L. Deen, Said M. Ali Assessment and comparative analysis of a rapid diagnostic test (Tubex<sup>®</sup>) for the diagnosis of typhoid fever among hospitalized children in rural Tanzania. BMC Infectious Diseases. Vol.11, (2011). doi:10.1186/1471-2334-11-147 Retrieved from: https://repository.li.mahidol.ac.th/handle/20.500.14594/12499
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
Assessment and comparative analysis of a rapid diagnostic test (Tubex<sup>®</sup>) for the diagnosis of typhoid fever among hospitalized children in rural Tanzania
Abstract
Background: Typhoid fever remains a significant health problem in many developing countries. A rapid test with a performance comparable to that of blood culture would be highly useful. A rapid diagnostic test for typhoid fever, Tubex ® , is commercially available that uses particle separation to detect immunoglobulin M directed towards S almonella Typhi O9 lipopolysaccharide in sera.Methods: We assessed the sensitivity and specificity of the Tubex test among Tanzanian children hospitalized with febrile illness using blood culture as gold standard. Evaluation was done considering blood culture confirmed S. Typhi with non-typhi salmonella (NTS) and non - salmonella isolates as controls as well as with non-salmonella isolates only.Results: Of 139 samples tested with Tubex, 33 were positive for S. Typhi in blood culture, 49 were culture-confirmed NTS infections, and 57 were other non-salmonella infections. Thirteen hemolyzed samples were excluded. Using all non - S. Typhi isolates as controls, we showed a sensitivity of 79% and a specificity of 89%. When the analysis was repeated excluding NTS from the pool of controls we showed a sensitivity of 79% and a specificity of 97%. There was no significant difference in the test performance using the two different control groups (p > 0.05).Conclusion: This first evaluation of the Tubex test in an African setting showed a similar performance to those seen in some Asian settings. Comparison with the earlier results of a Widal test using the same samples showed no significant difference (p > 0.05) for any of the performance indicators, irrespective of the applied control group. © 2011 Ley et al; licensee BioMed Central Ltd.