Publication:
Treatment of four industrial wastewaters by sequencing batch reactors: Evaluation of COD, TKN and TP removal

dc.contributor.authorP. Fongsatitkulen_US
dc.contributor.authorD. G. Warehamen_US
dc.contributor.authorP. Elefsiniotisen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherUniversity of Canterburyen_US
dc.contributor.otherUniversity of Aucklanden_US
dc.date.accessioned2018-07-12T02:27:13Z
dc.date.available2018-07-12T02:27:13Z
dc.date.issued2008-11-01en_US
dc.description.abstractThis study investigated the ability of a sequencing batch reactor (SBR) system to treat four industrial wastewaters, namely, textile, landfill leachate, seafood and slaughterhouse effluents. The system employed three identical SBRs (10 l volume each) operating in parallel and each waste was treated one at a time. The operational variables examined included the length of the non-aerated period and the solids retention time (SRT). All four wastewaters experienced chemical oxyfen demand (COD) and total kjeldhal nitrogen (TKN) removals greater than 81%, while the TP removals were lower, ranging from 57 to 94%. The length of the non-aerated period appeared to have minimal effect on the SBR performance; however, increases in SRT reduced the percent TP removal for the textile and leachate wastes only. In addition, to investigate organic loading limits to the seafood SBR system, the COD was increased by three increments of 250 mg l-1 starting from a baseline concentration of 1100 mg l-1. This resulted in a reduction in both the TKN and TP removal at the higher concentrations. Finally, for the slaughterhouse wastewater, the COD:TKN ratio was tested at levels of 6:1, 8:1 and 9:1 with the result that only the TP removal was affected at the lowest ratio. © Taylor & Francis, 2008.en_US
dc.identifier.citationEnvironmental Technology. Vol.29, No.11 (2008), 1257-1264en_US
dc.identifier.doi10.1080/09593330802308978en_US
dc.identifier.issn1479487Xen_US
dc.identifier.issn09593330en_US
dc.identifier.other2-s2.0-52949098744en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/19227
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=52949098744&origin=inwarden_US
dc.subjectEnvironmental Scienceen_US
dc.titleTreatment of four industrial wastewaters by sequencing batch reactors: Evaluation of COD, TKN and TP removalen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=52949098744&origin=inwarden_US

Files

Collections