Publication:
A systematic review and meta-analysis of the diagnostic accuracy of rapid immunochromatographic assays for the detection of dengue virus IgM antibodies during acute infection

dc.contributor.authorStuart D. Blacksellen_US
dc.contributor.authorJenny A. Dousten_US
dc.contributor.authorPaul N. Newtonen_US
dc.contributor.authorSharon J. Peacocken_US
dc.contributor.authorNicholas P.J. Dayen_US
dc.contributor.authorArjen M. Dondorpen_US
dc.contributor.otherChurchill Hospitalen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherMahosot Hospitalen_US
dc.contributor.otherUniversity of Queenslanden_US
dc.date.accessioned2018-08-20T07:01:09Z
dc.date.available2018-08-20T07:01:09Z
dc.date.issued2006-08-01en_US
dc.description.abstractA meta-analysis of rapid (≤60 min) dengue diagnostic assays was conducted to determine accuracy and identify causes of between-study heterogeneity. A systematic review identified 302 potentially suitable studies, of which 11 were selected for meta-analysis. All selected studies evaluated the immunochromatographic test (ICT) manufactured by Panbio Pty Ltd. Individual study results for sensitivity ranged from 0.45 to 1.0, specificity 0.57-1.0, diagnostic odds ratio 4.5-1287, and positive:negative likelihood ratios 2.3-59 and 0.01-0.56, respectively. Results indicated that the ICT evaluated in the selected studies can both rule in and rule out disease but is more accurate when samples are collected later in the acute phase of infection. Limitations of this meta-analysis were significant between-study heterogeneity caused by inconsistencies in evaluation methodologies, and the evaluation of only the Panbio ICT. It is recommended that additional, standardized evaluations are required for other dengue ICTs. © 2005 Royal Society of Tropical Medicine and Hygiene.en_US
dc.identifier.citationTransactions of the Royal Society of Tropical Medicine and Hygiene. Vol.100, No.8 (2006), 775-784en_US
dc.identifier.doi10.1016/j.trstmh.2005.10.018en_US
dc.identifier.issn00359203en_US
dc.identifier.other2-s2.0-33646260354en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/23316
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33646260354&origin=inwarden_US
dc.subjectImmunology and Microbiologyen_US
dc.subjectMedicineen_US
dc.titleA systematic review and meta-analysis of the diagnostic accuracy of rapid immunochromatographic assays for the detection of dengue virus IgM antibodies during acute infectionen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33646260354&origin=inwarden_US

Files

Collections