Publication: Minimal detectable changes of the berg balance scale, fugl-meyer assessment scale, timed "up & go" test, gait speeds, and 2-minute walk test in individuals with chronic stroke with different degrees of ankle plantarflexor tone
Issued Date
2012-07-01
Resource Type
ISSN
1532821X
00039993
00039993
Other identifier(s)
2-s2.0-84863312096
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Bibliographic Citation
Archives of Physical Medicine and Rehabilitation. Vol.93, No.7 (2012), 1201-1208
Suggested Citation
Vimonwan Hiengkaew, Khanitha Jitaree, Pakaratee Chaiyawat Minimal detectable changes of the berg balance scale, fugl-meyer assessment scale, timed "up & go" test, gait speeds, and 2-minute walk test in individuals with chronic stroke with different degrees of ankle plantarflexor tone. Archives of Physical Medicine and Rehabilitation. Vol.93, No.7 (2012), 1201-1208. doi:10.1016/j.apmr.2012.01.014 Retrieved from: https://repository.li.mahidol.ac.th/handle/20.500.14594/14218
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
Minimal detectable changes of the berg balance scale, fugl-meyer assessment scale, timed "up & go" test, gait speeds, and 2-minute walk test in individuals with chronic stroke with different degrees of ankle plantarflexor tone
Other Contributor(s)
Abstract
Objective: To determine test-retest reliability and absolute and relative minimal detectable changes at the 95% confidence level (MDC 95 ) of measures to detect postural balance and lower limb movements in individuals with chronic stroke who were able to walk and had differences in ankle plantarflexor tone. Design: Test-retest study. Data were collected on 2 occasions, about 6 days apart. Setting: Outpatient physical therapy clinics. Participants: Volunteers (N=61) with chronic stroke who were able to walk and had differences in ankle plantarflexor tone: no increase in ankle plantarflexor tone (n=12), a slight increase in ankle plantarflexor tone (n=32), and a marked increase in ankle plantarflexor tone (n=17). Intervention: Not applicable. Main Outcome Measures: Reliability and absolute and relative MDC 95 of the Berg Balance Scale (BBS), the lower limb subscale of Fugl-Meyer Assessment (FMA-LE), the Timed "Up & Go" test (TUG), the comfortable gait speed (CGS), the fast gait speed (FGS), and the 2-minute walk test (2MWT). Results: Excellent reliability of the BBS, FMA-LE, TUG, CGS, FGS, and 2MWT for all the participants combined and for the subgroups was shown. All the participants combined showed the absolute and relative MDC 95 in the BBS of 5 points and 10%, FMA-LE of 4 points and 16%, TUG of 8 seconds and 28%, CGS of 0.2m/s and 34%, FGS of 0.1m/s and 21%, and 2MWT of 13m and 23%. The absolute and relative MDC 95 of the subgroups were varied based on ankle plantarflexor tone. Conclusions: The BBS, FMA-LE, TUG, CGS, FGS, and 2MWT are reliable measures to detect postural balance and lower limb movements in individuals with chronic stroke who have differences in ankle plantarflexor tone. The absolute and relative MDC 95 of each measure are dissimilar in those with differences in ankle plantarflexor tone. The relative MDC 95 seems more useful than the absolute MDC 95 because the relative value can be used for a single individual. © 2012 American Congress of Rehabilitation Medicine.