Publication:
64-slice MDCT angiography of upper extremity in assessment of native hemodialysis access

dc.contributor.authorJitladda Wasinraten_US
dc.contributor.authorThanongchai Siriapisithen_US
dc.contributor.authorSomrach Thamtorawaten_US
dc.contributor.authorTrongtum Tongdeeen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-05-03T08:37:56Z
dc.date.available2018-05-03T08:37:56Z
dc.date.issued2011-01-01en_US
dc.description.abstractObjective: To compare multidetector row computed tomographic (MDCT) angiography with conventional digital subtraction angiography (DSA) in the evaluation of vascular access stenoses in hemodialysis patients. Materials and methods: Twenty-one consecutive patients were imaged with MDCT angiography and subsequent DSA. The superficial vein of leg was used as the route for intravenous administration. The vascular stenosis was assessed in not significant ( < 50% stenosis), moderate stenosis (50%-74% stenosis), severe stenosis (75%-99%), and total occlusion (100%). The accuracy, sensitivity, specificity, positive, and negative predictive values were calculated for significant vascular stenosis using DSA as the standard reference. Results: The sensitivity and specificity of MDCT angiography for the detection of significant hemodialysis vascular access were 100% (95% CI, 89.3%-100%) and 94.8% (95% CI, 89.1%-97.6%), respectively. The positive and negative predictive values were 84.2% (95% CI, 68.1%-93.4%) and 100% (95% CI, 95.8%-100%), respectively. The accuracy of MDCT angiography for detection of significant stenoses was 95.9% (95% CI, 91.4%-97.0%). Conclusions: MDCT angiography provides excellent correlation in vascular stenosis as compared with DSA in hemodialysis access. Complete assessment of entire vascular segments could be performing with MDCT angiography in planning before endovascular intervention or surgical correction. © The Author(s) 2011.en_US
dc.identifier.citationVascular and Endovascular Surgery. Vol.45, No.1 (2011), 69-77en_US
dc.identifier.doi10.1177/1538574410379922en_US
dc.identifier.issn15385744en_US
dc.identifier.other2-s2.0-78650849721en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/12727
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=78650849721&origin=inwarden_US
dc.subjectMedicineen_US
dc.title64-slice MDCT angiography of upper extremity in assessment of native hemodialysis accessen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=78650849721&origin=inwarden_US

Files

Collections