Publication:
The use of nonfluoroscopic catheter-based mapping system to perform radiofrequency ablation in complex ventricular tachycardia after cardiac surgery in congenital heart disease : A case report

dc.contributor.authorCharn Sriratanasathavornen_US
dc.contributor.authorKertijai Bhuripanyoen_US
dc.contributor.authorOngkarn Raungratanaampornen_US
dc.contributor.authorRungroj Krittayaphongen_US
dc.contributor.authorKoonlawee Nademaneeen_US
dc.contributor.authorBurin Kwo-Sa-Arden_US
dc.contributor.authorSuphachai Chaithiraphanen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherUniv. of S. California Sch. of Med.en_US
dc.date.accessioned2018-09-07T09:17:21Z
dc.date.available2018-09-07T09:17:21Z
dc.date.issued2000-11-01en_US
dc.description.abstractA nonfluoroscopic electroanatomical cardiac mapping system (CARTO) integrates anatomical and electrophysiological information to reconstruct a three-dimensional activation map. Information from the CARTO system helps to reveal the mechanism and perform successful ablation in scar re-entry ventricular tachycardia after cardiac surgery. Three-dimensional activation and propagation mapping was performed in i. patient with ventricular tachycardia after surgical correction of a double outlet right ventricle. The ventricular tachycardia appeared in two morphologies and were refractory to antiarrhythmic medication including amiodarone. Both ventricular tachycardias were re-entered using the ventriculotomy scar but rotated in different directions. Successful radiofrequency ablation was performed by creating a line of conduction block from the pulmonic valve to the ventriculotomy scar using entrainment mapping and the ablation lesion tagging technique. The CARTO system is useful in mapping and guiding the ablation of complex ventricular tachycardia after surgical correction in congenital heart disease.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.83, No.SUPPL. 2 (2000)en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-0344005607en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/26148
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0344005607&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleThe use of nonfluoroscopic catheter-based mapping system to perform radiofrequency ablation in complex ventricular tachycardia after cardiac surgery in congenital heart disease : A case reporten_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0344005607&origin=inwarden_US

Files

Collections