Publication:
Rapid and sensitive detection of shrimp yellow head virus by loop-mediated isothermal amplification combined with a lateral flow dipstick

dc.contributor.authorSasiwarat Khunthongen_US
dc.contributor.authorWansadaj Jaroenramen_US
dc.contributor.authorNarong Arunruten_US
dc.contributor.authorRungkarn Suebsingen_US
dc.contributor.authorIdsada Mungsantisuken_US
dc.contributor.authorWansika Kiatpathomchaien_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherCenter of Excellence on Agricultural Biotechnology: (AG-BIO/PERDO-CHE)en_US
dc.contributor.otherThailand National Center for Genetic Engineering and Biotechnologyen_US
dc.date.accessioned2018-10-19T05:05:09Z
dc.date.available2018-10-19T05:05:09Z
dc.date.issued2013-03-01en_US
dc.description.abstractYellow head virus (YHV) is a highly virulent pathogen that has caused severe mortality in cultivated shrimp (Penaeus monodon and Penaeus vannamei) in Thailand. There are several technologies that are applied to detect YHV for further control of the disease. RT-PCR is currently widely used in the laboratory, but it has some disadvantages related to cost, time-consuming and complexity. An alternative assay combines RT with loop-mediated isothermal amplification (LAMP) that not only provides high specificity, sensitivity and rapidity, but is also cheaper and more suitable for field applications in shrimp aquaculture than the RT-PCR. RT-LAMP is performed under isothermal conditions with a set of four to six primers designed to recognize six to eight distinct target sequences, and it has been combined with a chromatographic lateral-flow dipstick (LFD) to detect LAMP amplified product, which avoids the use of gel electrophoresis. In this study, RT-LAMP for the detection of YHV was developed by isothermal amplification at 65. °C for 45. min, followed by hybridization with an FITC-labeled DNA probe for 5. min and detected by LFD within 5. min (time required approximately 55. min, excluding RNA extraction and preparation time). The detection limit of RT-LAMP-LFD was 0.1. pg RNA extracted from shrimp infected with YHV equivalent to the nested RT-PCR, and no cross reaction was observed with other common shrimp viral pathogens. The LAMP method described in this study showed a rapid, high sensitivity and specificity and it is recommended as user-friendly for diagnosis of YHV in the field. © 2012 Elsevier B.V.en_US
dc.identifier.citationJournal of Virological Methods. Vol.188, No.1-2 (2013), 51-56en_US
dc.identifier.doi10.1016/j.jviromet.2012.11.041en_US
dc.identifier.issn18790984en_US
dc.identifier.issn01660934en_US
dc.identifier.other2-s2.0-84871944601en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/31955
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84871944601&origin=inwarden_US
dc.subjectImmunology and Microbiologyen_US
dc.titleRapid and sensitive detection of shrimp yellow head virus by loop-mediated isothermal amplification combined with a lateral flow dipsticken_US
dc.typeReviewen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84871944601&origin=inwarden_US

Files

Collections