Publication: Unfocused effect on the measurement of ocular aberrations
dc.contributor.author | Sabong Srivannaboon | en_US |
dc.contributor.author | Narisara Adulbhan | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.date.accessioned | 2018-06-21T08:21:06Z | |
dc.date.available | 2018-06-21T08:21:06Z | |
dc.date.issued | 2005-11-01 | en_US |
dc.description.abstract | Objectives: To evaluate the effect of unfocused measurement in the value of ocular aberrations. Material and Method: The present study was conducted at Siriraj Hospital, Mahidol University. Ocular aberrations of 20 eyes in 10 myopic patients (myopia less than -6.00 diopters (D) and astigmatism less than -2.00 diopters (D)) were analyzed by using Zywave aberrometer® (Bausch & Lomb, USA). The measurements were done at the pupillary plane (focus) and 6 other different planes (unfocus); 5, 10 and 15 mm inside and outside pupillary plane respectively. The value of each measurement was analyzed to find the effect of unfocused measurement on ocular aberrations. Results: The magnitude of error (root mean square, RMS) of the spherical component of refraction at 5, 10, 15 mm inside and outside the pupillary plane was 0.16, 0.44, 0.57 D and 0.21, 0.38, 1.35 D respectively. The RMS of astigmatic component of refraction inside and outside the pupillary plane at the same distance was 0.19, 0.50, 0.80 and 0.18, 0.52, 1.55 D respectively. The RMS of higher order aberrations inside and outside the pupillary plane at the same distance was 0.05, 0.13, 0.15 and 0.06, 0.1, 0.1 microns respectively. Conclusion: There was more effect of outward unfocused measurement in the value of refraction (spherical and astigmatism) than inward unfocused measurement. Higher order aberration showed a similar error in both inward and outward defocus. The magnitude of error was 10 - 12% within 5 mm unfocused planes. | en_US |
dc.identifier.citation | Journal of the Medical Association of Thailand. Vol.88, No.SUPPL. 9 (2005) | en_US |
dc.identifier.issn | 01252208 | en_US |
dc.identifier.issn | 01252208 | en_US |
dc.identifier.other | 2-s2.0-31544435474 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/16748 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=31544435474&origin=inward | en_US |
dc.subject | Medicine | en_US |
dc.title | Unfocused effect on the measurement of ocular aberrations | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=31544435474&origin=inward | en_US |