Publication: Efficacy of the Ramathibodi nasal filter in a simulated human airway evaluated by a laser diode portable dust monitor under low laser smoke particle concentration
1
item.page.dc.date.issued
2002-02-01
item.page.dc.type
item.page.dc.identifier.issn
01252208
item.page.dc.identifier.other
2-s2.0-0036463988
item.page.dc.rights
Mahidol University
item.page.dc.rights.holder
SCOPUS
item.page.dc.identifier.citation
Journal of the Medical Association of Thailand. Vol.85, No.2 (2002), 195-199
punsarn.item.page.citation
Kunchitthape Tanpowpong, Chumroon Chiratthiti Efficacy of the Ramathibodi nasal filter in a simulated human airway evaluated by a laser diode portable dust monitor under low laser smoke particle concentration. Journal of the Medical Association of Thailand. Vol.85, No.2 (2002), 195-199. Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/20543
Research Projects
Organizational Units
Authors
Journal Issue
relationships.isThesisOf
item.page.dc.title
Efficacy of the Ramathibodi nasal filter in a simulated human airway evaluated by a laser diode portable dust monitor under low laser smoke particle concentration
item.page.dc.contributor.author
item.page.dc.contributor.other
item.page.dc.description.abstract
The Ramathibodi nasal filter attached to a simulated human airway was proposed to filter laser smoke particles. The simulated human airway composed of nasal and pharyngeal model, airway passage and lung model machine which mimicked the human respiratory system. The laser smoke particles represented a suspended particulate matter in a highly air-pollutted area such as at a main roadside in Bangkok. The experiment was done in the Department cf Otolaryngology, Ramathibodi Hospital, from January to March 2000. The simulated human airway got an equal amount of laser smoke particles in a sealed plastic box for 1 min. The residual amount of laser smoke particles in a closed system of the simulated human airway was measured by a laser diode portable dust monitor for 1 min in each cycle and calculated as a mean and standard deviation. Without the Ramathibodi nasal filter of 39 sample pairs, the amounts of PM15, PM10 and PM2.5 were 52.3 ± 6.8, 43.0 ± 4.9 and 37.0 ± 3.5 mcg/m3 respectively. With the Ramathibodi nasal filter of 39 pairs sample, the amounts of PM15, PM10 and PM2.5 were 48.1 ± 9.9, 39.1 ± 9.1 and 33.2 ± 7.2 mcg/m3 respectively. Ramathibodi nasal filter efficacy for all laser smoke particle sizes evaluated statistically using t-test showed significant differences from those without the filter. Filtration efficacy should be tested further in higher concentrations of laser smoke particles and applied in human nasal vestibules under a critical air-polluted condition.