Publication:
High throughput assay for the determination of piperaquine in plasma

dc.contributor.authorN. Lindegårdhen_US
dc.contributor.authorN. J. Whiteen_US
dc.contributor.authorN. P J Dayen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherNuffield Department of Clinical Medicineen_US
dc.date.accessioned2018-06-21T08:11:35Z
dc.date.available2018-06-21T08:11:35Z
dc.date.issued2005-09-15en_US
dc.description.abstractA high throughput assay for the determination of the antimalarial piperaquine in plasma has been developed and validated. The assay utilises 96-wellplate formats throughout the whole procedure, and easily enables a throughput of 192 samples a day using a single LC system. Buffer (pH 2.0; 0.05 M) containing internal standard was added to 0.25 mL plasma in a 96-wellplate (2 mL wells). The samples were extracted on a MPC solid phase extraction deep well 96-wellplate (3 M Empore). Piperaquine and internal standard were analysed by liquid chromatography with UV detection on a Chromolith Performance (100 mm × 4.6 mm) column with a mobile phase containing acetonitrile-phosphate buffer (pH 2.5; 0.1 M) (8:92, v/v) at a flow rate of 3.0 mL/min. The within-day precisions for piperaquine were 3.3 and 2.3% at 40 and 1250 ng/mL, respectively. The between-day precisions for piperaquine were 5.8 and 1.3% at 40 and 1250 ng/mL, respectively. The total assay precisions using 29 replicates over 5 days were 6.7, 4.5 and 2.7% at 40, 200 and 1250 ng/mL, respectively. The lower limit of quantification (LLOQ) and the limit of detection (LOD) were 10 and 5 ng/mL, respectively using 0.25 mL plasma. Using 1 mL of plasma, it was possible to decrease LLOQ and LOD to 2.5 and 1.25 ng/mL, respectively. © 2005 Elsevier B.V. All rights reserved.en_US
dc.identifier.citationJournal of Pharmaceutical and Biomedical Analysis. Vol.39, No.3-4 (2005), 601-605en_US
dc.identifier.doi10.1016/j.jpba.2005.03.031en_US
dc.identifier.issn07317085en_US
dc.identifier.other2-s2.0-23944465725en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/16431
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=23944465725&origin=inwarden_US
dc.subjectChemistryen_US
dc.subjectPharmacology, Toxicology and Pharmaceuticsen_US
dc.titleHigh throughput assay for the determination of piperaquine in plasmaen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=23944465725&origin=inwarden_US

Files

Collections