Publication:
A comparison of non-magnetic and magnetic beads for measuring IgG antibodies against Plasmodium vivax antigens in a multiplexed bead-based assay using Luminex technology (Bio-Plex 200 or MAGPIX)

dc.contributor.authorRamin Mazharien_US
dc.contributor.authorJessica Brewsteren_US
dc.contributor.authorRich Fongen_US
dc.contributor.authorCaitlin Bourkeen_US
dc.contributor.authorZoe S.J. Liuen_US
dc.contributor.authorEizo Takashimaen_US
dc.contributor.authorTakafumi Tsuboien_US
dc.contributor.authorWai Hong Thamen_US
dc.contributor.authorMatthias Harbersen_US
dc.contributor.authorChetan Chitnisen_US
dc.contributor.authorJulie Healeren_US
dc.contributor.authorMaria Ome-Kaiusen_US
dc.contributor.authorJetsumon Sattabongkoten_US
dc.contributor.authorJames Kazuraen_US
dc.contributor.authorLeanne J. Robinsonen_US
dc.contributor.authorChristopher Kingen_US
dc.contributor.authorIvo Muelleren_US
dc.contributor.authorRhea J. Longleyen_US
dc.contributor.otherPapua New Guinea Institute of Medical Researchen_US
dc.contributor.otherWalter and Eliza Hall Institute of Medical Researchen_US
dc.contributor.otherUniversity of Melbourneen_US
dc.contributor.otherRikenen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherBurnet Instituteen_US
dc.contributor.otherEhime Universityen_US
dc.contributor.otherInstitut Pasteur, Parisen_US
dc.contributor.otherCase Western Reserve Universityen_US
dc.contributor.otherCellFree Sciences Co., Ltd.en_US
dc.date.accessioned2020-12-28T03:42:23Z
dc.date.available2020-12-28T03:42:23Z
dc.date.issued2020-12-01en_US
dc.description.abstract© 2020 Mazhari et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Multiplexed bead-based assays that use Luminex® xMAP® technology have become popular for measuring antibodies against proteins of interest in many fields, including malaria and more recently SARS-CoV-2/COVID-19. There are currently two formats that are widely used: non-magnetic beads or magnetic beads. Data are lacking regarding the comparability of results obtained using these two types of beads, and for assays run on different instruments. Whilst non-magnetic beads can only be run on flow-based instruments (such as the Luminex® 100/200™ or Bio-Plex® 200), magnetic beads can be run on both these and the newer MAGPIX® instruments. In this study we utilized a panel of purified recombinant Plasmodium vivax proteins and samples from malaria-endemic areas to measure P. vivax-specific IgG responses using different combinations of beads and instruments. We directly compared: i) non-magnetic versus magnetic beads run on a Bio-Plex® 200, ii) magnetic beads run on the Bio-Plex® 200 versus MAGPIX® and iii) non-magnetic beads run on a Bio-Plex® 200 versus magnetic beads run on the MAGPIX®. We also performed an external comparison of our optimized assay. We observed that IgG antibody responses, measured against our panel of P. vivax proteins, were moderately-strongly correlated in all three of our comparisons (pearson r>0.5 for 18/19 proteins), however higher amounts of protein were required for coupling to magnetic beads. Our external comparison indicated that results generated in different laboratories using the same coupled beads are also highly comparable (pearson r>0.7), particularly if a reference standard curve is used.en_US
dc.identifier.citationPLoS ONE. Vol.15, No.12 December (2020)en_US
dc.identifier.doi10.1371/journal.pone.0238010en_US
dc.identifier.issn19326203en_US
dc.identifier.other2-s2.0-85097310947en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/60345
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85097310947&origin=inwarden_US
dc.subjectAgricultural and Biological Sciencesen_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.titleA comparison of non-magnetic and magnetic beads for measuring IgG antibodies against Plasmodium vivax antigens in a multiplexed bead-based assay using Luminex technology (Bio-Plex 200 or MAGPIX)en_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85097310947&origin=inwarden_US

Files

Collections