Publication:
The influence of blade type and feeding force during resin bonded dentin specimen preparation on the microtensile bond strength test

dc.contributor.authorApinya Limvisitsakulen_US
dc.contributor.authorSuppason Thitthaweeraten_US
dc.contributor.authorPisol Senawongseen_US
dc.contributor.otherMahidol University, Faculty of Dentistryen_US
dc.date.accessioned2022-08-04T08:38:34Z
dc.date.available2022-08-04T08:38:34Z
dc.date.issued2021-01-01en_US
dc.description.abstractThis paper presents the effect of blade type and feeding force during resin-bonded dentin specimen preparation on the microtensile bond strength (µTBS) test. Forty resin-bonded flat middle dentin specimens were divided into four groups. The specimens of each group were sectioned according to type of blade and feeding force as follows: fine grit/20 N, fine grit/40 N, medium grit/20 N, and medium grit/40 N to obtain resin-dentin sticks with a cross-sectional area of 1.0 mm2 . Four sticks from the center of each tooth were subjected to the µTBS test. Five remaining sticks of each group were selected for surface topography observation under a scanning electron microscope (SEM). As a result, the bond strength of the medium-grit group was higher than that of the fine-grit group (p < 0.001), whereas the feeding force had no influence on bond strength values (p = 0.648). From the SEM, sticks prepared with the fine-grit blade showed a smoother surface integrity and fewer defects on the specimen edges in comparison with the sticks prepared with the medium-grit blade. The grit type of the blade is one of the considerable factors that may affect the bond strength and the surface integrity of resin-dentin specimens for microtensile testing.en_US
dc.identifier.citationMicromachines. Vol.12, No.4 (2021)en_US
dc.identifier.doi10.3390/mi12040450en_US
dc.identifier.issn2072666Xen_US
dc.identifier.other2-s2.0-85105141427en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/76985
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85105141427&origin=inwarden_US
dc.subjectEngineeringen_US
dc.titleThe influence of blade type and feeding force during resin bonded dentin specimen preparation on the microtensile bond strength testen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85105141427&origin=inwarden_US

Files