Publication: Evaluation of CDC light traps for mosquito surveillance in a malaria endemic area on the Thai-Myanmar border
3
item.page.dc.date.issued
2015-12-15
item.page.dc.type
item.page.dc.identifier.issn
17563305
item.page.dc.identifier.doi
item.page.dc.identifier.other
2-s2.0-84949980850
item.page.dc.rights
Mahidol University
item.page.dc.rights.holder
SCOPUS
item.page.dc.identifier.citation
Parasites and Vectors. Vol.8, No.1 (2015)
punsarn.item.page.citation
Patchara Sriwichai, Stephan Karl, Yudthana Samung, Suchada Sumruayphol, Kirakorn Kiattibutr, Anon Payakkapol, Ivo Mueller, Guiyun Yan, Liwang Cui, Jetsumon Sattabongkot Evaluation of CDC light traps for mosquito surveillance in a malaria endemic area on the Thai-Myanmar border. Parasites and Vectors. Vol.8, No.1 (2015). doi:10.1186/s13071-015-1225-3 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/36031
Research Projects
Organizational Units
Authors
Journal Issue
relationships.isThesisOf
item.page.dc.title
Evaluation of CDC light traps for mosquito surveillance in a malaria endemic area on the Thai-Myanmar border
item.page.dc.contributor.author
item.page.dc.contributor.other
item.page.dc.description.abstract
© 2015 Sriwichai et al. Background: Centers for Disease Control and Prevention miniature light traps (CDC-LT) baited with CO2are a routine tool for adult mosquito sampling used in entomological surveys, and for monitoring and surveillance of disease vectors. The present study was aimed at evaluating the performance of baited and unbaited CDC-LT for indoor and outdoor trapping of endemic mosquito species in northwestern Thailand. Methods: CDC-LT (n = 112) with and without dry ice baits were set both indoors and outdoors in 88 selected houses for stretches of 5 consecutive nights per month in 7 villages in Tha Song Yang district, Tak province between January 2011 and March 2013. Individual traps were repeatedly placed in the same location for a median of 6 (range 1-10) times. Mosquitoes were identified by morphological characteristics and classified into blood-fed, empty, male/female and gravid. Absolute mosquito numbers were converted to capture rates (i.e., mosquitoes per trap and year). Capture rates were compared using multilevel negative binomial regression to account for multiple trap placements and adjust for regional and seasonal differences. Results: A total of 6,668 mosquitoes from 9 genera were collected from 576 individual CDC-LT placements. Culex was the predominant captured genus (46 %), followed by anopheline mosquitoes (45 %). Overall, CO2baited traps captured significantly more Culex (especially Culex vishnui Theobald) and Anopheles mosquitoes per unit time (adjusted capture rate ratio (aCRR) 1.64 and 1.38, respectively). Armigeres spp. mosquitoes were trapped in outdoor traps with significantly higher frequency (aCRR: 1.50), whereas Aedes albopictus (Skuse) had a tendency to be trapped more frequently indoors (aCRR: 1.89, p = 0.07). Furthermore, capture rate ratios between CO2baited and non-baited CDC-LT were significantly influenced by seasonality and indoor vs. outdoor trap placement. Conclusion: The present study shows that CDC-LT with CO2baiting capture significantly more Culex and Anopheles mosquitoes, some of which (e.g., Cx. vishnui, Cx. quinquefasciatus Say, An. minimus s.l. Theobald, An. maculatus s.l. Theobald) represent important disease vectors in Thailand. This study also shows significant differences in the capture efficiency of CDC-LT when placed indoors or outdoors and in different seasons. Our study thus provides important guidelines for more targeted future vector trapping studies on the Thai-Myanmar border, which is an important cross-border malaria transmission region in Thailand.
