Publication:
Normative values of second-trimester maternal serum markers using an automated assay platform for down syndrome screening

dc.contributor.authorKusol Russameecharoenen_US
dc.contributor.authorKatika Nawapunen_US
dc.contributor.authorBuraya Phattanachindakunen_US
dc.contributor.authorVitaya Titapanten_US
dc.contributor.authorTuangsit Wataganaraen_US
dc.contributor.authorNisarat Phithakwatcharaen_US
dc.contributor.otherFaculty of Medicine, Siriraj Hospital, Mahidol Universityen_US
dc.date.accessioned2020-01-27T10:22:31Z
dc.date.available2020-01-27T10:22:31Z
dc.date.issued2019-01-01en_US
dc.description.abstract© 2019 Siriraj Medical Journal. Objective: Automated chemiluminescent immunoassay has several advantages over manual ELISA with comparable test performance. Few studies have reported the reference values of the second-trimester serum markers maternal serum alpha-fetoprotein (AFP), human chorionic gonadotropin (hCG), unconjugated estriol (uE3), and inhibin A (Inh A) by automated immunoassay in Asian population. Accordingly, this study aimed to determine the median values of second trimester serum markers as a function of gestational age (GA) in Thai population using an automated immunoassay. Methods: This prospective cross-sectional study of serum markers in healthy singleton second trimester (14-22 weeks) pregnant women was conducted at Siriraj Hospital from September 2012 to April 2015. Maternal serum AFP, hCG, uE3, and Inh A were analyzed by automated immunoassay. Predicted median values as a function of GA were calculated from best-fit regression equations. Results: A total of 1,526 women were included. Median values serum markers were constructed from the following optimal models: AFP (ng/mL) = 99.082 - 14.195 GA + 0.662 GA 2 , r 2 =0.995; hCG (mIU/mL) = 390168.106 - 35 968.397GA + 876.708GA 2 , r 2 =0.972; uE3 (ng/mL) = -3.388 + 0.274 GA, r 2 =0.997; and, Inh-A (pg/mL) = 1206.875 - 114.171 GA + 3.174 GA 2 , r 2 =0.882. Using the same platform analysis and maternal weight adjustment, the reference values in Thai population were shown to be different from those of other ethnicities. Conclusion: Median values of second-trimester serum markers for Thai population were determined. Maternal weight and the use of population-specific normal values have to be taken into account for Down syndrome screening in the second trimester.en_US
dc.identifier.citationSiriraj Medical Journal. Vol.71, No.1 (2019), 21-24en_US
dc.identifier.doi10.33192/Smj.2019.04en_US
dc.identifier.issn22288082en_US
dc.identifier.other2-s2.0-85063488060en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/52129
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85063488060&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleNormative values of second-trimester maternal serum markers using an automated assay platform for down syndrome screeningen_US
dc.typeArticleen_US