Publication: An investigation of fluoride release from orthodontic elastomeric ligatures
10
item.page.dc.date.issued
2014-01-01
item.page.dc.type
item.page.dc.identifier.issn
16628985
10226680
10226680
item.page.dc.identifier.doi
item.page.dc.identifier.other
2-s2.0-84913582719
item.page.dc.rights
Mahidol University
item.page.dc.rights.holder
SCOPUS
item.page.dc.identifier.citation
Advanced Materials Research. Vol.1025-1026, (2014), 787-791
punsarn.item.page.citation
Nuttachai Viriyakosol, Surachai Dechkunakorn, Niwat Anuwongnukroh, Peerapong Tua-Ngam, Wassana Wichai An investigation of fluoride release from orthodontic elastomeric ligatures. Advanced Materials Research. Vol.1025-1026, (2014), 787-791. doi:10.4028/www.scientific.net/AMR.1025-1026.787 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/33862
Research Projects
Organizational Units
Authors
Journal Issue
relationships.isThesisOf
item.page.dc.title
An investigation of fluoride release from orthodontic elastomeric ligatures
item.page.dc.contributor.author
item.page.dc.contributor.other
item.page.dc.description.abstract
© (2014) Trans Tech Publications, Switzerland. Amount of fluoride release in test group was greater than in the control group in all 3 brands. Within 7 days of daily fluoride exposure, the fluoride released from elastomeric ligatures was continuously increased. Fluoride release from Morelli (0.067±0.013 ppm) and Unitek (0.067±0.012 ppm) were significantly higher than Thai (0.040±0.03 ppm). The fluoride level measured from Morelli and Unitek were not significantly different. The orthodontic elastomeric ligatures can absorb fluoride from mouthwash and release the detectable amount of fluoride within seven days. This fluoride might help prevention of enamel decalcification adjacent to the bracket during orthodontic treatment.The study aimed to investigate the amount of fluoride release from 3 brands of elastomeric ligatures in vitro, after exposure to daily fluoride mouthrinse. The study used 3 brands of elastomeric ligatures (Morelli, Brazil; Unitek, USA; Thai, Thailand). Two elastomeric ligatures from each brand were moistened by de-ionized water and then divided into control and test groups (n=5 per group). In both groups, elastomeric ligatures were placed in individual plastic bottle with 3 ml of de-ionized water. However, In the test group, They were exposed to fluoride mouthrinse (250 ppm fluoride/0.05%NaF) for 1 minute daily. All samples were stored at 37°C for 1, 3, 5, 7 days. After the end of each observation period, the amount of fluoride release in de-ionized water was measured by fluoride ion electrode. The data were analyzed by Kraskal-Wallis and Mann-Whitney U tests (p<0.05).