Publication:
Comparison of conventional and OATz ablation profiles for laser in situ keratomileusis to correct myopia up to -10.00 diopters

dc.contributor.authorAnun Vongthongsrien_US
dc.contributor.authorNutharin Phusitphoykaien_US
dc.contributor.authorJanpen Siriboonkoomen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherTRSC International LASIK Centeren_US
dc.date.accessioned2018-07-24T03:48:39Z
dc.date.available2018-07-24T03:48:39Z
dc.date.issued2004-09-01en_US
dc.description.abstractPURPOSE: To compare results of laser in situ keratomileusis (LASIK) using two different ablation profiles for correction of myopia between -0.50 and -10.00 D with the Nidek NAVEX system. METHODS: In a prospective nonrandomized study, 249 myopic eyes (151 patients) had LASIK for correction of myopia. The Nidek MK-2000 micro-keratome and the Nidek NAVEX excimer laser system were used in all eyes. Conventional LASIK was performed in 112 eyes of 64 patients with a 6.0-mm ablation zone and 7.5-mm transition zone (conventional group). LASIK with the Nidek OATz ablation profile was performed in 137 eyes of 87 patients, with variable ablation and transition zones (OATz group). Mean baseline manifest refraction was -4.11 ± 1.83 D in the conventional group and -5.45 ± 2.27 D in the OATz group. Baseline best spectacle-corrected visual acuity was 20/20 or better in 83.9% of eyes in the conventional group and 81.0% of eyes in the OATz group. RESULTS: Mean follow-up was 3.6 months (range 3 to 8 mo). At last follow-up, manifest refraction was within ±0.50 D of emmetropia in 86% of eyes (within ±1.00 D in 99.1%) in the conventional group and 94.2% of eyes (within ±1.00 D in 100%) in the OATz group. Uncorrected visual acuity was 20/40 or better in all eyes. No eyes in either group lost 2 or more lines of BSCVA. CONCLUSIONS: The Nidek NAVEX system was safe and predictable in correcting myopia up to -10.00 D with the OATz ablation profile. OATz LASIK was similar to conventional LASIK in both refractive and visual outcomes.en_US
dc.identifier.citationJournal of Refractive Surgery. Vol.20, No.5 SUPPL. (2004)en_US
dc.identifier.issn1081597Xen_US
dc.identifier.other2-s2.0-4644260724en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/21548
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=4644260724&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleComparison of conventional and OATz ablation profiles for laser in situ keratomileusis to correct myopia up to -10.00 dioptersen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=4644260724&origin=inwarden_US

Files

Collections