Publication:
A LC/MS/MS method for determination of tenofovir in human plasma and its application to toxicity monitoring

dc.contributor.authorNarit Wiriyakosolen_US
dc.contributor.authorApichaya Puangpetchen_US
dc.contributor.authorWeerawut Manosuthien_US
dc.contributor.authorSasinapha Tomongkonen_US
dc.contributor.authorChonlaphat Sukasemen_US
dc.contributor.authorDarawan Pinthongen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherKratumbaan Hospitalen_US
dc.contributor.otherBamradnaradoon Hospitalen_US
dc.date.accessioned2019-08-23T10:33:34Z
dc.date.available2019-08-23T10:33:34Z
dc.date.issued2018-05-15en_US
dc.description.abstract© 2018 Elsevier B.V. Tenofovir disoproxil fumarate is a pro-drug of the active metabolite tenofovir widely used against the HIV1, HIV2, and Hepatitis B virus. Several studies have been conducted and found kidney injury associated with tenofovir exposure. High tenofovir plasma concentration correlated with kidney injury in tenofovir-exposed patients. The present study developed and validated a simple and cost-effective LC/MS/MS method to determine tenofovir level in human plasma. A small plasma volume of 80 μl is utilized for the sample preparation. The samples were separated by Luna C18 (100 mm × 2.0 mm, 3 μm) using gradient elution with a mobile phase consisting of water (containing 0.1% formic acid) and acetonitrile (90:10, v/v). The detection was achieved through multiple reaction monitoring using positive ionization mode on the triple quadrupole mass spectrometer with a run time of 10 min. The monitoring transitions were set at m/z 288.0 → 176.1 and 136.1 for tenofovir and m/z 226.1 → 152.0 for acyclovir (as the internal standard). This standard curve was linear from 10 to 640 ng/ml, with the lower limit of quantification of 10 ng/ml. The inter- and intra-day precision results were less than 12.3% and their accuracies were within the acceptable range of 84.9–113.1%. The validated method was successfully applied to the study of tenofovir induced kidney injury in HIV-1 infected patients taking 300 mg once daily for more than 4 weeks.en_US
dc.identifier.citationJournal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences. Vol.1085, (2018), 89-95en_US
dc.identifier.doi10.1016/j.jchromb.2018.03.045en_US
dc.identifier.issn1873376Xen_US
dc.identifier.issn15700232en_US
dc.identifier.other2-s2.0-85049848525en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/45166
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85049848525&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.titleA LC/MS/MS method for determination of tenofovir in human plasma and its application to toxicity monitoringen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85049848525&origin=inwarden_US

Files

Collections