Publication: A LC/MS/MS method for determination of tenofovir in human plasma and its application to toxicity monitoring
dc.contributor.author | Narit Wiriyakosol | en_US |
dc.contributor.author | Apichaya Puangpetch | en_US |
dc.contributor.author | Weerawut Manosuthi | en_US |
dc.contributor.author | Sasinapha Tomongkon | en_US |
dc.contributor.author | Chonlaphat Sukasem | en_US |
dc.contributor.author | Darawan Pinthong | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Kratumbaan Hospital | en_US |
dc.contributor.other | Bamradnaradoon Hospital | en_US |
dc.date.accessioned | 2019-08-23T10:33:34Z | |
dc.date.available | 2019-08-23T10:33:34Z | |
dc.date.issued | 2018-05-15 | en_US |
dc.description.abstract | © 2018 Elsevier B.V. Tenofovir disoproxil fumarate is a pro-drug of the active metabolite tenofovir widely used against the HIV1, HIV2, and Hepatitis B virus. Several studies have been conducted and found kidney injury associated with tenofovir exposure. High tenofovir plasma concentration correlated with kidney injury in tenofovir-exposed patients. The present study developed and validated a simple and cost-effective LC/MS/MS method to determine tenofovir level in human plasma. A small plasma volume of 80 μl is utilized for the sample preparation. The samples were separated by Luna C18 (100 mm × 2.0 mm, 3 μm) using gradient elution with a mobile phase consisting of water (containing 0.1% formic acid) and acetonitrile (90:10, v/v). The detection was achieved through multiple reaction monitoring using positive ionization mode on the triple quadrupole mass spectrometer with a run time of 10 min. The monitoring transitions were set at m/z 288.0 → 176.1 and 136.1 for tenofovir and m/z 226.1 → 152.0 for acyclovir (as the internal standard). This standard curve was linear from 10 to 640 ng/ml, with the lower limit of quantification of 10 ng/ml. The inter- and intra-day precision results were less than 12.3% and their accuracies were within the acceptable range of 84.9–113.1%. The validated method was successfully applied to the study of tenofovir induced kidney injury in HIV-1 infected patients taking 300 mg once daily for more than 4 weeks. | en_US |
dc.identifier.citation | Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences. Vol.1085, (2018), 89-95 | en_US |
dc.identifier.doi | 10.1016/j.jchromb.2018.03.045 | en_US |
dc.identifier.issn | 1873376X | en_US |
dc.identifier.issn | 15700232 | en_US |
dc.identifier.other | 2-s2.0-85049848525 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/45166 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85049848525&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Chemistry | en_US |
dc.title | A LC/MS/MS method for determination of tenofovir in human plasma and its application to toxicity monitoring | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85049848525&origin=inward | en_US |