Amperometric flow injection analysis of glucose using immobilized glucose oxidase on nano-composite carbon nanotubes-platinum nanoparticles carbon paste electrode

dc.contributor.authorMaliwan Amatatongchaien_US
dc.contributor.authorWongduan Sroyseeen_US
dc.contributor.authorSanoe Chairamen_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.otherUbon Rajathanee Universityen_US
dc.contributor.otherFlow Innovation-Research for Science and Technology Laboratories (FIRST Labs.en_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-12-21T06:49:31Z
dc.date.accessioned2019-03-14T08:02:53Z
dc.date.available2018-12-21T06:49:31Z
dc.date.available2019-03-14T08:02:53Z
dc.date.issued2017-05-01en_US
dc.description.abstract© 2015 Elsevier B.V. We report a novel amperometric glucose biosensor based on glucose oxidase (GOx) immobilized on a carbon nanotube (CNTs)–poly(diallyldimethyl-ammonium chloride) (PDDA)–platinum nanoparticle (PtNPs) modified carbon-paste electrode (CNTs–PDDA–PtNPs/CPE). The CNTs–PDDA–PtNPs composite materials were characterized by TEM and electrochemical techniques. Cyclic voltammetric results reveal direct electron transfer of the immobilized GOx, indicated by two quasi-reversible redox peaks at a potential of 0.37 V (vs. Ag/AgCl) in phosphate buffered solution (PBS) (0.10 M, pH 7). The biosensor provides good glucose oxidation activity and retention of GOx electrocatalytic activity due to CNTs–PDDA–PtNPs enhancement of the redox response. The carbon paste electrode was installed as working electrode in a flow through electrochemical cell of a flow injection (FI) system. Glucose was quantified using amperometric measurements at 0.5 V vs. Ag/AgCl and PBS carrier (0.10 M, pH 7.0) at a flow rate of 1.0 mL min−1. The linear working ranges for glucose measurements were 0.1–3 mM (r2=0.995) and 5–100 mM (r2=0.997), with corresponding sensitivities of 0.127 and 0.060 (μA s) mM−1, respectively. The system provides good precision of 2.8% R.S.D with a calculated detection limit (3 S/N) of 15 μM. The proposed method was successfully applied to determination of glucose in food and pharmaceutical samples with throughput of 200 samples h−1.en_US
dc.identifier.citationTalanta. Vol.166, (2017), 420-427en_US
dc.identifier.doi10.1016/j.talanta.2015.11.072en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-84949646249en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/41875
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84949646249&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.titleAmperometric flow injection analysis of glucose using immobilized glucose oxidase on nano-composite carbon nanotubes-platinum nanoparticles carbon paste electrodeen_US