dc.description.abstract© 2018, Medical Association of Thailand. All rights reserved. Objective: To determine inter-fraction errors from setup and target motion of prostate cancer treated with intensity modulated radiation therapy [IMRT] by using on-board cone beam computed tomography [CBCT]. Materials and Methods: We analyzed retrospective data of on-board CBCT images of 14 prostate cancers over 395 sessions. We performed image matching of CBCT and planning CT, using two methods, prostate soft tissue matching to determine total error (tumor motion and setup error), and bone matching for setup error only. Target motion values were estimated by subtracting setup error from total error. Systematic error of target motion and setup error were calculated from individual mean values. Results: Inter-fraction errors for target motion were 0.9±0.6 mm (0 to 8 mm), 0.7±0.5 mm (0 to 6 mm), and 0.5±0.3 mm (0 to 6 mm) for vertical [Vrt], longitudinal [Lng], and lateral [Lat] directions, respectively. Inter-fraction of setup errors were 2.7±1.2 mm (0 to 13 mm) for Vrt direction, 2.2±1.0 mm (0 to 8 mm) for Lng, and 2.8±1.6 mm (0 to 14 mm) for Lat. Conclusion: With bone matching, planning target volume [PTV] margins should be at least 6 mm in all directions. Systematic setup errors are within 3 mm in all directions.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.101, No.6 (2018), S87-S92en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-85064210268en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/46628
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85064210268&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleAssessment of inter-fraction target motion using on-board imaging system for prostate canceren_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85064210268&origin=inwarden_US

Files

Collections