Publication:
Assessing Extravascular Lung Water in Critically Ill Patients Using Lung Ultrasound: A Systematic Review on Methodological Aspects in Diagnostic Accuracy Studies

dc.contributor.authorOwen B. Neuteboomen_US
dc.contributor.authorMicah L. Heldewegen_US
dc.contributor.authorLuigi Pisanien_US
dc.contributor.authorMarry R. Smiten_US
dc.contributor.authorWim K. Lagranden_US
dc.contributor.authorThomas G. Cherpanathen_US
dc.contributor.authorArjen M. Dondorpen_US
dc.contributor.authorMarcus J. Schultzen_US
dc.contributor.authorPieter R. Tuinmanen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherVrije Universiteit Amsterdamen_US
dc.contributor.otherUniversiteit van Amsterdamen_US
dc.date.accessioned2020-05-05T05:07:35Z
dc.date.available2020-05-05T05:07:35Z
dc.date.issued2020-01-01en_US
dc.description.abstract© 2020 World Federation for Ultrasound in Medicine & Biology Lung ultrasound (LUS) is a non-invasive bedside method used to quantify extravascular lung water (EVLW). To evaluate the methodology and diagnostic accuracy of LUS in studies assessing EVLW in intensive care unit patients, PubMed and Embase were searched for studies comparing LUS with imaging modalities. In 14 relevant studies a wide variety of equipment used and training of examiners were noted. Four scoring systems were reported: (i) a binary score (the presence of three or more B-lines); (ii) a categorical score; (iii) a numerical score; (iv) a quantitative LUS score using software. The diagnostic accuracy of LUS varied: sensitivity ranged from 50%–98%, specificity from 76%–100% and r² from 0.20–0.91. Methodology and diagnostic accuracy varies substantially in published reports. Further research is needed to correlate methodological factors with diagnostic accuracy. Hospitals should standardize LUS methodology. Consensus is needed to harmonize LUS methodology for lung water assessment.en_US
dc.identifier.citationUltrasound in Medicine and Biology. (2020)en_US
dc.identifier.doi10.1016/j.ultrasmedbio.2020.02.014en_US
dc.identifier.issn1879291Xen_US
dc.identifier.issn03015629en_US
dc.identifier.other2-s2.0-85082670594en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/54488
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85082670594&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectHealth Professionsen_US
dc.subjectPhysics and Astronomyen_US
dc.titleAssessing Extravascular Lung Water in Critically Ill Patients Using Lung Ultrasound: A Systematic Review on Methodological Aspects in Diagnostic Accuracy Studiesen_US
dc.typeReviewen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85082670594&origin=inwarden_US

Files

Collections