Publication:
Techniques and results of off-pump coronary artery bypass grafting using homemade intracoronary shunt

dc.contributor.authorSuchart Chaiyarojen_US
dc.contributor.authorSomchai Viengteeravaten_US
dc.contributor.authorWipapon Bhumaranguraen_US
dc.contributor.authorSiam Khajarernen_US
dc.contributor.authorParinya Leelayanaen_US
dc.contributor.authorBoontiva Purintrapibanen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-08-20T07:09:34Z
dc.date.available2018-08-20T07:09:34Z
dc.date.issued2006-10-11en_US
dc.description.abstractBackground: The outcome of the off-pump coronary artery bypass grafting (CABG) is highly dependent on surgical techniques. To overcome problems of intraoperative hemodynamic instability and avoid potential injury to coronary artery arising from occlusive technique, the authors have modified the strategy of performing distal anastomosis by using the authors' homemade intracoronary artery shunt. Objective: To document the results of off-pump CABG using the authors' homemade intracoronary shunt. The characteristics of shunt and techniques are demonstrated. Material and Method: The shunt is constructed from silicone tubing (Allied Biomedical Company, Paso Robles, CA). It has been successfully used for distal anastomoses in off-pump coronary artery bypass surgery. All 170 consecutive patients who had off-pump CABG from October 2002 to May 2005 were evaluated. Data were collected retrospectively. Average grafts per patient were 3.5. Arterial grafts were used in most cases (90%). Conversion rate was 2.8%. Patients were followed up at 3 weeks, 6 weeks, and bimonthly thereafter. Results: In a 23-month follow-up, the operative mortality rate was 0.5% (one patient). Complications included stroke in 3 patients (1.8%) and post-operative AF in 12 patients (7.12%). Of 170 patients, 12 patients (7.05%) required intraoperative or postoperative intraaortic balloon pump support. The early results were good and satisfactory. Conclusion: Off-pump CABG can be successfully performed using the authors' homemade intracoronary artery shunt with better hemodynamic control. The techniques are safe, simple, reliable, and effective.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.89, No.9 (2006), 1434-1439en_US
dc.identifier.issn01252208en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-33749453232en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/23538
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33749453232&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleTechniques and results of off-pump coronary artery bypass grafting using homemade intracoronary shunten_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33749453232&origin=inwarden_US

Files

Collections