Publication:
Accuracy of the StatStrip versus SureStep Flexx glucose meter in neonates at risk of hypoglycemia

dc.contributor.authorRatchada Kitsommarten_US
dc.contributor.authorSopapan Ngernchamen_US
dc.contributor.authorPimol Wongsiridejen_US
dc.contributor.authorTharatip Kolataten_US
dc.contributor.authorKriang Sak Jirapaeten_US
dc.contributor.authorBosco Paesen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherMcMaster University, Faculty of Health Sciencesen_US
dc.date.accessioned2018-10-19T05:24:58Z
dc.date.available2018-10-19T05:24:58Z
dc.date.issued2013-05-06en_US
dc.description.abstractThe study was performed to evaluate the accuracy of the StatStrip (SS) and SureStep Flexx (SF) glucose meters compared to plasma glucose in infants at risk for neonatal hypoglycemia and to determine the effect of bilirubin and hematocrit on the results. A prospective cross-sectional study was conducted on 172 venous blood glucose samples from infants who had initial low point-of-care (POC) glucose tests measured simultaneously by SS and SF. Plasma glucose levels were compared to both POC instruments, and the effect of bilirubin and hematocrit levels on mean glucose differences were analysed. Mean (SD) plasma glucose was 2.12 (0.45) mmol/L; (range, 1.11-3.06 mmol/L). Mean (1.96SD) glucose differences of the SS versus SF were 0.21 (0.70) mmol/L and -0.04 (0.78)mmol/L, respectively. SS sensitivity was 94.7 % with an 86.1 % negative predictive value (NPV) at 2.8 mmol/L, while the SF had a 100 % sensitivity and NPV at the same cut-off level. No correlations were identified between mean glucose differences and either hematocrit or bilirubin levels in both glucose meters. Both the SS and SF glucose meters have limited use when compared to plasma glucose. Hence, they can only be employed as screening tools in at-risk neonates with an appropriate, predetermined cut-off level. Hematocrit and bilirubin levels did not affect the accuracy of both devices.en_US
dc.identifier.citationEuropean Journal of Pediatrics. Vol.172, No.9 (2013), 1181-1186en_US
dc.identifier.doi10.1007/s00431-013-2019-2en_US
dc.identifier.issn14321076en_US
dc.identifier.issn03406199en_US
dc.identifier.other2-s2.0-84892824614en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/32345
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84892824614&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleAccuracy of the StatStrip versus SureStep Flexx glucose meter in neonates at risk of hypoglycemiaen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84892824614&origin=inwarden_US

Files

Collections