Publication:
Comparison of femoral component rotational axes in computer-assisted total knee arthroplasty using the gap technique: A retrospective study

dc.contributor.authorThanaphot Channoomen_US
dc.contributor.authorPithinatt Mangklanontachaien_US
dc.contributor.authorPatarawan Woratanaraten_US
dc.contributor.authorSiwadol Wongsaken_US
dc.contributor.authorPaphon Sa-Ngasoongsongen_US
dc.contributor.authorViroj Kawinwonggowiten_US
dc.contributor.otherFaculty of Medicine, Ramathibodi Hospital, Mahidol Universityen_US
dc.contributor.otherThonburi Hospitalen_US
dc.date.accessioned2019-08-28T06:20:46Z
dc.date.available2019-08-28T06:20:46Z
dc.date.issued2018-03-01en_US
dc.description.abstract© 2018, Medical Association of Thailand. All rights reserved. Objective: To compare the deviation of three femoral rotational axes in computer assisted surgery [CAS] total knee arthroplasty [TKA] using the gap technique. Materials and Methods: A retrospective cross-sectional study was conducted between 2004 and 2013 at the Department of Orthopaedics, Ramathibodi Hospital of patients who had undergone computer-assisted total knee arthroplasty. All patients were included with the exception of those who had had post-traumatic knee osteoarthritis, valgus knee, or trapezoidal medial-lateral gap. Baseline characteristics and femoral rotational axes (Whiteside, posterior condyle, and transepicondyle) were recorded. Comparison among the three axes was performed using analysis of variance. Results: The study included 140 patients (114 women and 26 men) with an average age of 71.6±8.4 years, representing 140 total knee arthroplasties. The deviation of femoral component rotation axes were: Whiteside’s line 0.42±4.49 degrees, posterior condylar line -1.43±4.82 degrees and transepicondylar line -3.93±5.00 (p<0.001). Conclusion: Whiteside’s line showed the smallest deviation in femoral component rotation compared to the gap technique in CAS TKA.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.101, No.3 (2018), S95-S100en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-85064218531en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/46879
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85064218531&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleComparison of femoral component rotational axes in computer-assisted total knee arthroplasty using the gap technique: A retrospective studyen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85064218531&origin=inwarden_US

Files