Publication:
Changes in resin-infiltrated dentin stiffness after water storage

dc.contributor.authorS. Chiaraputten_US
dc.contributor.authorS. Maien_US
dc.contributor.authorB. P. Huffmanen_US
dc.contributor.authorR. Kapuren_US
dc.contributor.authorK. A. Ageeen_US
dc.contributor.authorC. K Y Yiuen_US
dc.contributor.authorD. C N Chanen_US
dc.contributor.authorC. Harnirattisaien_US
dc.contributor.authorD. D. Arolaen_US
dc.contributor.authorF. A. Rueggebergen_US
dc.contributor.authorD. H. Pashleyen_US
dc.contributor.authorF. R. Tayen_US
dc.contributor.otherSrinakharinwirot Universityen_US
dc.contributor.otherSun Yat-Sen Universityen_US
dc.contributor.otherMedical College of Georgiaen_US
dc.contributor.otherThe University of Hong Kongen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherUniversity of Maryland, Baltimore Countyen_US
dc.date.accessioned2018-07-12T02:25:17Z
dc.date.available2018-07-12T02:25:17Z
dc.date.issued2008-07-01en_US
dc.description.abstractPlasticization of polymers by water sorption lowers their mechanical properties in a manner that is predictable by the polarity of their component resins. This study tested the hypothesis that when adhesive resins were used to create resin-infiltrated dentin, the reductions in their flexural moduli after water storage would be lowered proportional to their hydrophilic characteristics. Three increasingly hydrophilic resin blends were used to fabricate polymer beams and macro-hybrid layer models of resin-infiltrated dentin for testing with a miniature three-point flexure device, before and after 1-4 weeks of water storage. Flexural modulus reductions in macro-hybrid layers were related to, and more extensive than, reductions in the corresponding polymer beams. Macro-hybrid layers that were more hydrophilic exhibited higher percent reductions in flexural modulus, with the rate of reduction proportional to the Hoy's solubility parameters for total intermolecular attraction forces (δt) and polar forces (δp) of the macrohybrid layers.en_US
dc.identifier.citationJournal of Dental Research. Vol.87, No.7 (2008), 655-660en_US
dc.identifier.doi10.1177/154405910808700704en_US
dc.identifier.issn00220345en_US
dc.identifier.other2-s2.0-47649109084en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/19163
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=47649109084&origin=inwarden_US
dc.subjectDentistryen_US
dc.titleChanges in resin-infiltrated dentin stiffness after water storageen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=47649109084&origin=inwarden_US

Files

Collections