Publication:
Quality assurance of VMAT on flattened and flattening filter-free accelerators using a high spatial resolution detector

dc.contributor.authorF. S. Mataren_US
dc.contributor.authorD. Wilkinsonen_US
dc.contributor.authorJ. Davisen_US
dc.contributor.authorG. Biasien_US
dc.contributor.authorT. Causeren_US
dc.contributor.authorI. Fudulien_US
dc.contributor.authorO. Braceen_US
dc.contributor.authorN. Stansooken_US
dc.contributor.authorM. Carolanen_US
dc.contributor.authorA. B. Rosenfelden_US
dc.contributor.authorMarco Petaseccaen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherUniversity of Wollongongen_US
dc.contributor.otherWollongong Hospitalen_US
dc.contributor.otherIHMRIen_US
dc.date.accessioned2020-05-05T05:56:24Z
dc.date.available2020-05-05T05:56:24Z
dc.date.issued2020-01-01en_US
dc.description.abstract© 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine Purpose: This study investigated the use of high spatial resolution solid-state detectors (DUO and Octa) combined with an inclinometer for machine-based quality assurance (QA) of Volumetric Modulated Arc Therapy (VMAT) with flattened and flattening filter-free beams. Method: The proposed system was inserted in the accessory tray of the gantry head of a Varian 21iX Clinac and a Truebeam linear accelerator. Mutual dependence of the dose rate (DR) and gantry speed (GS) was assessed using the standard Varian customer acceptance plan (CAP). The multi-leaf collimator (MLC) leaf speed was evaluated under static gantry conditions in directions parallel and orthogonal to gravity as well as under dynamic gantry conditions. Measurements were compared to machine log files. Results: DR and GS as a function of gantry angle were reconstructed using the DUO/inclinometer and in agreement to within 1% with the machine log files in the sectors of constant DR and GS. The MLC leaf speeds agreed with the nominal speeds and those extracted from the machine log files to within 0.03 cm s−1. The effect of gravity on the leaf motion was only observed when the leaves traveled faster than the nominal maximum velocity stated by the vendor. Under dynamic gantry conditions, MLC leaf speeds ranging between 0.33 and 1.42 cm s−1 were evaluated. Comparing the average MLC leaf speeds with the machine log files found differences between 0.9% and 5.7%, with the largest discrepancy occurring under conditions of fastest leaf velocity, lowest DR and lowest detector signal. Conclusions: The investigation on the use of solid-state detectors in combination with an inclinometer has demonstrated the capability to provide efficient and independent verification of DR, GS, and MLC leaf speed during dynamic VMAT delivery. Good agreement with machine log files suggests the detector/inclinometer system is a useful tool for machine-specific VMAT QA.en_US
dc.identifier.citationJournal of Applied Clinical Medical Physics. (2020)en_US
dc.identifier.doi10.1002/acm2.12864en_US
dc.identifier.issn15269914en_US
dc.identifier.other2-s2.0-85083364423en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/54678
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85083364423&origin=inwarden_US
dc.subjectMedicineen_US
dc.subjectPhysics and Astronomyen_US
dc.titleQuality assurance of VMAT on flattened and flattening filter-free accelerators using a high spatial resolution detectoren_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85083364423&origin=inwarden_US

Files

Collections