Publication: A microfluidic paper-based analytical device for type-II pyrethroid targets in an environmental water sample
dc.contributor.author | Sumate Pengpumkiat | en_US |
dc.contributor.author | Jintana Nammoonnoy | en_US |
dc.contributor.author | Watcharaporn Wongsakoonkan | en_US |
dc.contributor.author | Pajaree Konthonbut | en_US |
dc.contributor.author | Pornpimol Kongtip | en_US |
dc.contributor.other | Valaya Alongkorn Rajabhat University | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | National Institute of Metrology (Thailand) | en_US |
dc.date.accessioned | 2020-08-25T09:02:09Z | |
dc.date.available | 2020-08-25T09:02:09Z | |
dc.date.issued | 2020-08-01 | en_US |
dc.description.abstract | © 2020 by the authors. Licensee MDPI, Basel, Switzerland. A detection method for type-II pyrethroids in an environmental water sample using a microfluidic paper-based analytical device (µPAD) is reported here. The detection approach is based on the formation of cyanide from the hydrolysis of type-II pyrethroids and the colorimetric detection of cyanide on a layer-based µPAD. Parafilm and inexpensive laminating pouches were used to create a hydrophobic barrier for the assay on the µPAD. This detection approach was selective to type-II pyrethroids in water for which an environmental water sample was tested. The calibration curves for cypermethrin, deltamethrin, cyhalothrin, and fenvalerate ranged from 2 to 40 µg/mL without sample preconcentration. The lower concentrations of type-II pyrethroids can be assessed by including a preconcentration step prior to the detection on a µPAD. This detection system provides an alternative platform for fast, semiquantitative testing for pesticide contamination in environmental surface water by allowing for portability, low reagent/sample consumption, and low-cost testing. | en_US |
dc.identifier.citation | Sensors (Switzerland). Vol.20, No.15 (2020), 1-15 | en_US |
dc.identifier.doi | 10.3390/s20154107 | en_US |
dc.identifier.issn | 14248220 | en_US |
dc.identifier.other | 2-s2.0-85088567853 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/57691 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85088567853&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Engineering | en_US |
dc.subject | Physics and Astronomy | en_US |
dc.title | A microfluidic paper-based analytical device for type-II pyrethroid targets in an environmental water sample | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85088567853&origin=inward | en_US |