dc.description.abstract© 2014 IEEE. Echocardiography provides information about size, shape, and function of heart to create the image. Apical four-chamber echocardiography can be obtained by placing the ultrasound probe at the apex of the left ventricle. Such view enables to analyze heart abnormalities. In this regard, chamber quantification is recommended to evaluate the heart volume by defining the endocardial border of the chambers. Image segmentation that subdivides an image into different regions may be suitable to analyze the chambers. In this study, we propose a Marker-controlled Watershed segmentation method. It involves Watershed Transform, internal and external markers, and morphological processing. The advantage is that it can control over-segmentation due to noise and other local irregularities. We tested the proposed method on an apical four-chamber echocardiography image and a model image. We also compared the segmentation result with an Active Contour-based segmentation method. The results show that the Watershed Transform performs better than Active Contour.en_US
dc.identifier.citationIECBES 2014, Conference Proceedings - 2014 IEEE Conference on Biomedical Engineering and Sciences: "Miri, Where Engineering in Medicine and Biology and Humanity Meet". (2015), 644-647en_US
dc.identifier.doi10.1109/IECBES.2014.7047583en_US
dc.identifier.other2-s2.0-84925678981en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/35911
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84925678981&origin=inwarden_US
dc.subjectEngineeringen_US
dc.titleApical four-chamber echocardiography segmentation using Marker-controlled Watershed segmentationen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84925678981&origin=inwarden_US

Files

Collections